Skip to main content
Official casework recordDismissedCurrent release

Appeal 3264371

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

7 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

described as ‘Conversion of roofspace into habitable accommodation, re-application for proposal given permission in 2014 where work has not yet started.’

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Preliminary Matters

    The description of development given in the heading above is taken from the application form. However, the development proposed includes rear ground floor and roof extensions as set out in the decision notice which states ‘Construction of a single storey rear extension at [site address] , SE4, together with the construction of a rear dormer roof extension.’ The Council does not object to the proposed ground floor rear extension. I see no reason to disagree and have framed the main issue accordingly.

    The London Plan 2021 has been published since the decision was issued and now forms part of the development plan. Its policies supersede those of the London Plan 2016 cited in the decision notice. Nevertheless, the broad thrust of the 2021 policies referred to in this decision are consistent with the policies cited in the Council’s decision notice, on which the appellant had the opportunity to comment.

  3. Section 04

    Main Issue

    The main issue is the effect of the proposed roof extension on the character and appearance of the existing building, the terrace in which it sits and whether it would preserve or enhance the character and appearance of the Brockley Conservation Area.

  4. Section 05

    Reasons

    The appeal property forms part of a terrace. It is a two storey dwelling which sits between pairs of three storey dwellings. This is a repeated and distinctive feature which articulates the terrace and gives it a rhythm which reflects, to a degree, that found in the more established short terraces and pairs of buildings which characterise this part of the Conservation Area (CA). It therefore helps the terrace to contribute to the significance of the CA.

    The front wall of the proposed roof extension would project up on the line of the existing wall below, thereby not creating a set back or allowing space for tiling above the existing eaves level. The near flat roof of the extension would meet the existing roof at ridge level. Although the proposed rear elevation shows the roof extension set in from the sides of the existing property, there is a discrepancy in that the second floor plan shows the rooms at that level extending the full width of the property. In any event, the proposed extension would dominate the rear roof slope, leaving little or, if the second floor plan is correct, none of the existing tiling. As such, it would not comply with the Council’s Alterations and Extensions Supplementary Planning Document (SPD) which requires rear extensions to be set a minimum of 0.3m above the eaves line and 0.3m below the ridgeline.

    Nor would the roof extension accord with the SPD advice on roof extensions in CAs which requires them to be of exceptional design quality, set in significantly from the eaves, ridge and sides and no wider than two thirds of the original, unextended roof.

    The SPD also favours a contemporary design approach to large roof extensions in CAs. As the appellant notes, the proposed extension would be traditional insofar as it would have timber cladding. However, this material is not typical of buildings in this part of the CA. Moreover, the near flat roof, the scale and bulk of the extension and the large windows are not characteristic of traditional dormers. Therefore, the design cannot be regarded as ‘exceptional’ since it neither responds positively to its surroundings nor creates a pleasing contrast.

    The extension would also undermine the step down in the roof level which characterises the existing building and contributes to its significance to the CA. Although the roof extension would not be visible from the street, it would be visible from the rear gardens and windows of nearby properties and such views contribute to the appreciation of the CA.

    The appellant argues that the volume of the roof extension would be about half that allowed under permitted development rights. However such rights are not available in this case and the application must be determined in accordance with the development plan unless material considerations indicate otherwise.

    I find that the proposed roof extension would have a harmful effect on the character and appearance of the existing building and the terrace in which it sits and, consequently, would not preserve or enhance the character and appearance of the CA. It would, therefore, conflict with Policies D3 and HC1 of the London Plan 2021. These policies require development to respond to local character by identifying its special and valued features and characteristics, respect and enhance the features that contribute towards that character and to conserve the significance of heritage assets.

    The roof extension would also conflict with Policies 15 and 16 of the Council’s Core Strategy 2011 and Policies 30, 31 and 36 of its Development Management Local Plan 2014. Together, these policies seek high quality design which protects or enhances the historic environment, is compatible with the special 2 characteristics of the CA, contributes to local distinctiveness such as building features and roofscapes and, in the case of roof extensions, complements the form of the original building.

    Nor would the proposal accord with paragraph 197 of the National Planning Policy Framework (the Framework) which requires the desirability of sustaining and enhancing the significance of heritage assets to be taken into account. Although the harm to the heritage asset would be less than substantial, I am required to give great weight and importance to any harm to a designated heritage asset. In terms of the test at Framework paragraph 202, there would be no claimed public benefits of the proposal sufficient to outweigh that harm.

  5. Section 06

    Other Matters

    The appellant notes that the Council has not raised concerns regarding the effect of the proposal on the living conditions of neighbouring occupiers. However, the absence of further harm is not a positive point in favour of the proposal.

  6. Section 07

    Conclusion

    For the reasons set out above, the appeal should be dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 337No official casework-database value to compare
    Extracted decision date · page 1
    21 September 2021Matches the official casework database
    Extracted site visit dates
    14 September 2021 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3264371
Application reference
DC/20/115491
Lead case reference
Not recorded
Planning authority
London Borough of Lewisham
Planning authority code
E09000023

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
1
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Yes
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
3 December 2020
Valid date
13 January 2021
Start date
8 February 2021
Planning authority decision date
22 October 2020
Appeal decision date
21 September 2021

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
3458
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:25
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21