Permitted development under the GPDO in planning appeals

Compare source-linked planning appeal decisions from across England where the Inspector’s main issue matched the fixed “Permitted development under the GPDO” evidence query, by an exact configured phrase or close semantic meaning.

This page compares planning appeal decisions. It is not a count of planning-application refusal reasons and does not predict what would happen in a different case.

Matched decision families
537
542 appeal records represented
Matched appeal records
542
168 allowed · 372 dismissed · 2 other
Decision-text coverage
24,060 of 83,947
24,107 of 91,212 current appeal records

Local appeal evidence

Find evidence for your council or planning authority

Choose the council or planning authority that decided the application. Local pages are shown only where the published evidence snapshot meets the evidence and source checks.

Choose from 35 councils and planning authorities

Appeal evidence examples

Compare allowed and dismissed appeal reasoning

Each example separates the development, the Inspector-stated issue that selected it, and the reasoning from the decision. Compare the facts as well as the outcome: these examples do not predict how a different proposal would be decided.

Allowed appeal examples

1 example

  1. 6005525

    3 June 2026 · Allowed

    Development described in the decision

    described as: 6m single storey rear extension.

    Issue identified by the Inspector

    The main issue is whether the proposed development is permitted under Schedule 2, Part 1, Class A of the GPDO.

    Paragraph 5 · Source page 2

    Reasoning from the decision

    Whilst there is no definition within this part of the GPDO as to how eaves height is calculated, the Permitted Development Rights for Householders: Technical Guidance, updated 10 September 2019 (HTG) states that parapet walls should not be used in eaves height calculations. Moreover, the HTG provides an example, similar to the appellant’s proposed drawing, that shows that eaves height is measured to the top of the flat roof, excluding the parapet. As such, the eaves height in this case would not exceed 3 metres.

    Paragraph 8 · Source page 2

Dismissed appeal examples

4 examples

  1. 3348247

    24 February 2025 · Dismissed

    Development described in the decision

    a single storey rear extension.

    Issue identified by the Inspector

    The main issue is whether the proposed development would be permitted development under Schedule 2, Part 1, Class A of the GPDO.

    Paragraph 5 · Source page 1

    Reasoning from the decision

    In order to be permitted development under Class A, the proposal must meet all the limitations and conditions under this Class. [name].1(j) states that the development is not permitted by Class A if the enlarged part of the dwellinghouse would extend beyond a wall forming a side elevation of the original dwellinghouse and would (i) exceed 4 metres in height, (ii) have more than a single storey, or (iii) have a width greater than half the width of the original dwellinghouse.

    Paragraph 6 · Source pages 1, 2

  2. 3345223

    10 January 2025 · Dismissed

    Development described in the decision

    4m rear extension with pitched roof, redland 49 tiles to match existing, 2 velux windows, 4m bifold door to rear elevation.

    Issue identified by the Inspector

    The main issue is whether the proposed development would be permitted development under Schedule 2, Part 1, Class A of GPDO.

    Paragraph 3 · Source page 1

    Reasoning from the decision

    On the basis of the evidence before me, the proposal that would not accord with criterion A.1(j) of Part 1 of Class A. Consequently, the proposed development would not be permitted development under Article 3(1) and Schedule 2, Part 1, Class A of the GPDO.

    Paragraph 7 · Source page 2

  3. 3330069

    23 February 2024 · Dismissed

    Development described in the decision

    a single storey brick extension, with a warm tiled pitched roof.

    Issue identified by the Inspector

    The main issue is whether the proposed development would constitute permitted development under Schedule 2, Part 1, Class A of the GPDO.

    Paragraph 3 · Source page 1

    Reasoning from the decision

    Having regard to all of the above, I conclude that the proposed development would fail to comply with paragraph A.1(j) of Schedule 2, Part 1, Class A of the GPDO and so would not constitute permitted development.

    Paragraph 7 · Source page 2

  4. 3363946

    27 June 2025 · Dismissed

    Development described in the decision

    the erection of a single storey rear larger home extension, which would project 8.00m from the rear elevation, comprising a maximum height of 4.00m and eaves height of 2.50m.

    Issue identified by the Inspector

    The main issue is whether the proposed development would be permitted development under Class A of Part 1 of Schedule 2 of the GPDO.

    Paragraph 5 · Source page 1

    Reasoning from the decision

    [name].1 (h) states that development is not permitted by Class A if the enlarged part of the dwellinghouse would have more than a single storey and (h)(i) extend beyond the rear wall of the original dwellinghouse by more than 3 metres. While the proposal would enlarge the ground floor of the dwelling, the plans indicate that the extension would be joined to the approved first floor enlargement. Consequently, given the requirements of sub-paragraph A.1 (ja). the total enlargement comprising the proposed extension and the approved first floor enlargement, would fail to accord with sub-paragraph A.1 (h) of the GPDO.

    Paragraph 9 · Source page 2