Appeal 3270009
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
5 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
described as ‘Build an extension to the rear of the property, single storey in the back garden, no more than 5 metres long and under 6 metres wide within the boundary of the property, height will be no more than 3 metres in height with a pitched tiled roof (within the government building rules allowed). Extension will be made to accommodate a toilet and walk-in shower/wet room to the side partitioned off within the extension due to my ill health (heart patient) as I sometimes struggle to walk up the stairs, when in pain and get breathlessness.’
Section 02
Decision
The appeal is dismissed.
Section 03
Procedural Matters
The provisions of the GPDO, under Article 3 (1) and Schedule 2, Part 1, Class A, [name].4 (7) require the local planning authority to assess the proposed development solely on the basis of its impact on the amenity of any adjoining premises, taking into account any representations received. I have determined the appeal on the same basis.
The description of development above is taken from the application form. In the decision notice, the Council describes the development as a ‘Prior notification application for the construction of a single storey rear extension. The proposed extension will extend beyond the rear wall by 5.00 metres. The maximum height of the proposed extension from the natural ground level is 3.00 metres. The height at eaves level of the proposed extension measured from the natural ground level is 2.50 metres.’
During my site visit I observed that the proposed development the subject of this appeal appeared to be part-built.
Section 04
Main Issue
The main issue in this case is the effect of the proposed development on the amenity of the occupiers of Nos 7 and [address].
Section 05
Reasons
The appeal property is a two storey mid-terrace dwelling located within a residential area.
Like other dwellings in this short row of dwellings, the appeal property is set back from the road behind a front garden and it has a long garden to the rear.
The proposed development would extend across the full width of the original dwelling and project some 6 metres to the rear. [name] observed during my site visit that tall fencing to either side of the appeal property’s rear garden provides for privacy, the proposed development would extend to a height considerably above that of the fence.
I also noted during my site visit that neither of the adjoining neighbours to each side of the appeal property, Nos 7 and [address], have any significant extensions to the rear close to the appeal property. Consequently, the proposed development would dominate the outlook from the rear of both of these dwellings as it would appear as a tall, blank wall that would project immediately alongside the shared rear boundaries between Nos 7 and 8 and between Nos 8 and 9, for some considerable distance. 10.Resultantly, I find that the combined effect of the height, projection and immediate proximity of the proposed development would lead the proposal to appear unduly dominant, to an overbearing degree, when seen from the rear of both Nos 7 and [address]. 11.Further, the harm arising from this would be exacerbated as a result of the proposal being located to the south of No 9’s rear patio area. I find that this, together with the height, immediate proximity and overall scale of the proposal would inevitably lead to a reduction in the amount of daylight received by this area and there is no substantive evidence before me to the contrary. 12.For these reasons, the proposal would cause unacceptable harm to the amenity of the occupiers of Nos 7 and [address].
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 601No official casework-database value to compare
- Extracted decision date · page 1
- 9 July 2021Matches the official casework database
- Extracted site visit dates
- 18 June 2021 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3270009
- Application reference
- 21/00091/PRIEXT
- Lead case reference
- Not recorded
- Planning authority
- London Borough of Barking and Dagenham Council
- Planning authority code
- E09000002
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- 20 m²
- Number of residences
- 1
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 1 March 2021
- Valid date
- 11 March 2021
- Start date
- 4 May 2021
- Planning authority decision date
- 26 February 2021
- Appeal decision date
- 9 July 2021
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 480
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:25
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21