Skip to main content
Official casework recordAllowedCurrent release

Appeal 3272275

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

6 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

“loft conversion with rear dormer and alterations to roof from hip to gable”.

  1. Section 02

    Decision

    The appeal is allowed and attached to this decision is a certificate of lawful use or development describing the proposed operation which is considered to be lawful.

  2. Section 03

    Preliminary Matters

    In this type of appeal, the onus of proof is firmly upon the appellant. For the avoidance of doubt, the planning merits of the proposal are not relevant, and they are not an issue for me to consider in the context of an appeal under section 195 of the 1990 Act as amended. As such, I am not able to take account of the comments of an interested person since matters concerning loss of privacy and appearance would relate to planning merits.

    I consider that this appeal can be determined without the need for a site visit. This is because I have been able to reach a decision based on the information already available.

  3. Section 04

    Main Issue

    The main issue is whether the Council’s decision to refuse to grant a lawful development certificate (LDC) was well-founded.

  4. Section 05

    Reasons

    The appeal property is a semi-detached house, which has been extended previously to the side and rear. The appellant is now seeking a loft conversion with a rear dormer extension and alterations to the hipped roof to form a gable. The appellant’s case is that the proposed roof extensions would have a total volume of 46.56 cubic metres and so the development would fall within that ‘permitted’ under Article 3 and Schedule 2, Part 1, Class B to the Town and Country Planning (General Permitted Development) (England) Order 2015 (GPDO).

    Class B grants deemed planning permission for development involving the enlargement of a dwellinghouse consisting of an addition or alteration to its roof, subject to conditions and limitations. [name].1(d) development is not permitted by Class B if the cubic content of the resulting roof space would exceed the cubic content of the original roof space by more than - (i) 40 cubic metres in the case of a terrace house, or (ii) 50 cubic metres in any other case.

    In addition under B.1(e), development is not permitted if it would consist of or include - (i) the construction or provision of a verandah, balcony or raised platform, or (ii) the installation, alteration or replacement of a chimney, flue or soil and vent pipe.

    The Council is of the opinion that the extension would not comply with B.1(d), because the property has previous extensions which are estimated to measure 78.7 cubic metres. It is argued that the addition of the proposed roof extensions would exceed the 50 cubic metres allowed.

    The Technical Guidance1 states that – “To be permitted development any additional roof space created must not increase the volume of the original roof space of the house by more than 40 cubic metres for terraced houses and 50 cubic metres for semi-detached and detached houses. Any previous enlargement to the original roof space in any part of the house must be included in this volume allowance. ‘Original roof space’ will be that roof space in the ‘original building’, which means a building as it existed on 1 July 1948 where it was built before that date, and as it was built if built after that date”.

    Therefore, development is not permitted under paragraph B.1(d) if the cubic content of the resulting [from the enlargement to the] roof space would exceed the cubic content of the original roof space by more than 50 cubic metres. Previous extensions that did not result in an enlargement to the original roof space do not form part of that calculation.

    On the basis of the appellant’s calculations for the roof space, which are not queried by the Council, the cubic content of the resulting roof space would not exceed the cubic content of the original roof space by more than 50 cubic metres and so the development proposed would be permitted under Class B.

    The Council further considers that the development would not comply with B.1(e)(i) because the plans show a Juliette balcony on the rear of the dormer window.

    The Technical Guidance states that – “Alterations to the roof of a house for loft conversions involving the creation of balconies are not permitted development and will require planning permission. A balcony is understood to be a platform with a rail, balustrade or parapet projecting outside an upper storey of a building. A ‘Juliet’ balcony, where there is no platform and therefore no external access, would normally be permitted development”.

    In this case, the plans show there would be no platform. As such, the Juliet balcony would also be considered permitted development. 1 MHCLG – Permitted Development Rights for Householders: Technical Guidance, September 2019.

  5. Section 06

    Conclusion

    I find, therefore, that the development proposed would fall within that ‘permitted’ under Article 3 and Schedule 2, Part 1, Class B to the GPDO, and so it would be permitted development.

    For the reasons given above I conclude, on the evidence now available, that the Council’s refusal to grant a certificate of lawful use or development in respect of loft conversion with rear dormer and alterations to the roof from hip to gable was not well-founded and that the appeal should succeed. I will exercise the powers transferred to me under section 195(2) of the 1990 Act as amended.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 678No official casework-database value to compare
    Extracted decision date · page 1
    8 July 2021Matches the official casework database

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3272275
Application reference
20LP/2086
Lead case reference
Not recorded
Planning authority
Liverpool City Council
Planning authority code
E08000012

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Lawful Development Certificate
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. The decision of the LPA refusing/refusing in part to grant a certificate of lawful use or development
Appeal reason
Refusal
Type detail
Unknown
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Allowed
Decision category
Allowed
Received date
31 March 2021
Valid date
1 April 2021
Start date
19 April 2021
Planning authority decision date
17 December 2020
Appeal decision date
8 July 2021

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
411
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:25
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
20 August 2026 at 16:25