Appeal 3273163
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
5 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
described as part single part double storey side and rear extension incorporated with existing single storey rear extension.
Section 02
Decision
The appeal is dismissed.
Section 03
[name]
The Council advise that planning permission has been granted for a similar set of ground floor and outrigger extensions to those proposed but without the first-floor rear extension element which remains a matter of contention between the main parties. In the circumstances, my decision focuses on that particular part of the appeal proposal.
Section 04
Main Issue
The main issue raised by this appeal is the effect the first-floor rear extension element of the development would have on the living conditions of the occupiers of [address], with particular reference to outlook.
Section 05
Reasons
The appeal property is a modest terraced house with a two-storey outrigger at the rear. No 3 has a similar arrangement and the space between their two outriggers is fairly narrow. The only first-floor window in the rear elevation of No 3 (there is a smaller one in the flank of the outrigger) is situated close to the boundary with No 4. The two properties consequently share a sensitive relationship with one another.
The outlook from the adjacent first floor window in No 3 will presently be limited to a degree by the outrigger that extends past it, although it will be slightly more generous to the other side. Part of the proposal would extend the rear wall of the property outwards at first floor level with a flat roof element just under the eaves. This would extend up to the party boundary and, according to the appellant’s figures, project 0.8m from the rear elevation.
The proposed extension would be close to the first-floor window in No 3. Along with No 3’s existing outrigger this would create a short but noticeable area immediately outside the window enclosed by walls on either side. This would mean that it would appear as an enclosing and visually intrusive element when viewed from No 3 and create an overbearing and oppressive feeling within the room that it serves. Although modest in projection compared to the outrigger, its proximity to No 3 means that this harmful effect would not be diminished by its depth.
The development would consequently harm the living conditions of the occupiers of No 3. This would be contrary to [name] D2 and DM D3 of the Sites and Policies Plan1 which, amongst other criteria, expect development to ensure the provision of quality of living conditions to adjoining buildings and avoid visual disturbance resulting from development diminishing the living conditions of existing residents.
The appellant points out that the depth of the extension would mean that it would avoid interfering with a 45° diagonal, horizontal line extrapolated from the centre of No 3’s window. However, neither main party have directed me to any policy or guidance where this is set out, nor in what circumstances such an approach would be applicable. In any event, given the constrained space between the two properties and the close proximity of No 3’s first-floor window to the proposed extension, these circumstances mean that this particular proposal would be harmful even if it were to avoid infringing a notional ’45° Rule’.
The appellant’s agent advises that they have implemented similar extensions in other council areas, however I have determined the appeal on its merits and in the particular circumstances at the appeal site and its neighbour. I have no details of these before me and I cannot be certain that all the circumstances were identical to those of this case. Nor can I be sure that local policy and guidance in force in those areas would be the same. Such other examples cannot weigh in favour of the appeal. Notwithstanding that they refused permission, even if the Council communicated some uncertainty or ambiguity about the acceptability of the scheme to the appellant, given my findings above, this does not lead me to a different conclusion.
For the above reasons the proposal would harm neighbours’ living conditions in conflict with the development plan. There are no material considerations that indicate the decision should be made other than in accordance with the development plan and therefore the appeal is dismissed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 91No official casework-database value to compare
- Extracted decision date · page 1
- 16 July 2021Matches the official casework database
- Extracted site visit dates
- 9 July 2021 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3273163
- Application reference
- 21/P0538
- Lead case reference
- Not recorded
- Planning authority
- London Borough of Merton
- Planning authority code
- E09000024
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Unknown
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- 7 m²
- Number of residences
- 1
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 15 April 2021
- Valid date
- 15 April 2021
- Start date
- 17 June 2021
- Planning authority decision date
- 29 March 2021
- Appeal decision date
- 16 July 2021
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 860
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:25
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21