Skip to main content
Official casework recordAllowedCurrent release

Appeal 3282357

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

8 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

the construction of a single-storey, ground-floor rear extension.

  1. Section 02

    Decision

    The appeal is allowed and planning permission is granted for the construction of a single-storey, ground-floor rear extension at [site address] , in accordance with the terms of the application, Ref: 00371/98/P2, dated 7 May 2021, and the plans submitted with it, subject to the following conditions:

    The development hereby permitted shall begin not later than 3 years from the date of this decision.

    The development hereby permitted shall be carried out in accordance with the following approved plans: Location/Block Plan; [name] 101–114 inclusive.

    The materials to be used in the construction of the external surfaces of the extension hereby permitted shall match those used in the existing building.

  2. Section 03

    [name]

    The main issues in this case are the effect of the proposed extension on: • The character and appearance of Turnham Green Conservation Area, and • The living conditions of the occupiers of No [address] of light, outlook and sense of enclosure.

  3. Section 04

    Reasons

    No 98 is a semi-detached house situated on the eastern side of [address] at its southern end, close to its junction with the A4. It lies at the south-eastern corner of the Turnham Green Conservation Area (CA). In common with other houses along this part of [address], it is a house of significant depth with a long narrow garden to the rear.

    The appeal property has an L-shaped, single-storey rear extension, around 4.5 metres in depth at its southern end, at the boundary with the neighbouring No 100, and around 3 metres in depth at its northern end, at the boundary with No 96. This extension has a flat-roof with a height of around 3 metres. The boundaries of the rear gardens of Nos 96-100 turn very slightly to the north from the rear elevations of the houses, and each garden tapers inwards somewhat along the length of the rear gardens. The existing extension at the appeal property currently follows the boundary that slopes across the rear elevation of No 96 by a very small, but noticeable, amount.

    The proposed development would infill much of the space between the deep part of the existing extension and the side boundary with No 96. It would continue the line of the rear elevation of the existing extension up to a point between 0.6 metres and 0.9 metres away from that boundary, and it would continue the existing height of the extension of around 3 metres. Materials would match those existing. There is currently a 1.8 metre high fence along the line of the proposed side elevation of the infill development, and a further boundary fence lying on the property boundary a little to the north.

    Policy CC2 of the Council’s Local Plan (LP) requires developments to function well in themselves and in their effect on surrounding areas; to respond meaningfully and sensitively to the site, its characteristics and constraints; and provide adequate outlook, minimise over-bearingness and overshadowing, and ensure sufficient sunlight and daylight to adjoining/adjacent dwellings. Policy CC4 of the LP indicates that developments should conserve and take opportunities to enhance any heritage asset and its setting in a manner appropriate to its significance.

    Policy SC7 of the LP indicates that residential extensions should complement the original building, and minimise harm to neighbouring residents by way, for example, of avoiding an unacceptable loss of daylight/sunlight and outlook, or by creating an unacceptable sense of enclosure.

    The Council’s Residential Extensions Guide Supplementary Planning Document (SPD) indicates that it is important that single-storey rear extensions are secondary to the original house. They should not project too far from the rear wall of the original house as this could cause unacceptable enclosure and block daylight and sunlight received by neighbours. In the case of semi-detached houses, the maximum depth should 3.65m. Furthermore, in conservation areas, new extensions should never dominate in terms of bulk, scale or design

    The Council contends that the proposed extension, due to its cumulative depth with the existing extension would be an intrusive and unneighbourly addition, out of scale and character with this and surrounding dwellings, as well as having a serious and adverse effect on the neighbour's living conditions through loss of light, outlook and an increased sense of enclosure.

    The appellant contends that the infill extension would match the depth and height of the existing rear extension, and as such, would sit flush within the existing built form. The extension would also match the materials of the host property. For these reasons, the proposal would respect the host dwelling, and would not appear visually dominant. Moreover, while the proposed development would increase the overall depth of this new extension to above the maximum stated in the SPD, it would match the current height and depth of the existing extension and would not have any significant adverse effect on the sunlight or daylight received at the rear elevation of the adjacent No 96. Finally, he notes that there are already relatively new and large rear extensions at other houses along [address].

  4. Section 05

    Character and appearance

    In this case, the proposed infill extension would merely continue the rear elevation of the current building and would effectively round off the ground-floor rear elevation of the house. While this would increase the overall depth of this part of the existing extension to above the maximum stated in the SPD, it would not project and further beyond what is already there. It would add only a minimal amount to the current footprint and bulk of the house and would arguably represent an improvement to the appearance of the rear of the property. It would not be visible from the street nor, given the lengths of the rear gardens, would it be readily visible from the public realm or any other meaningful point at the rear.

    I note the existence of other examples of deep single-storey rear extensions at other properties along [address], but I have limited details of the background to these examples. In any case, I have dealt with this proposal on its own merits.

    On the basis of the above, I do not consider that the proposal would be intrusive or out-of-scale and character with its surroundings, and it would not be harmful to the character or appearance of the CA.

  5. Section 06

    Living conditions

    The proposed infill development would project a further 1.5 metres beyond the existing rear elevation of the southern section of the existing extension. It would, however, be set in from the boundary with No 96 by between around 0.6 metres closest to the house and 0.9 metres at the furthest extremity. Given that the existing building slopes a little across the rear elevation of the house at No 96, the new infill would be largely hidden from view from the patio doors/windows in the rear ground-floor elevation at the neighbouring property by the existing structure. In addition, it would be only around 1 metre higher than the fence that currently occupies the line of its proposed side elevation.

    The appellant has provided results of a sunlight and daylight survey that concludes that a good level of daylight would be retained at No 96, in accordance with BRE guidelines. There would be virtually no reduction in light when comparing the existing and proposed conditions, and where there would be reductions, they would be well within the BRE guidelines target criteria, ensuring the neighbouring occupants would not experience a noticeable reduction in daylight. Moreover, sunlight is not a material consideration as the windows face 90 degrees of due north.

    In the light of the above, I find that the proposed infill extension would effectively have little or no adverse reduction in light at rear of the neighbouring No 96. Furthermore, by virtue of its limited scale, the existing situation at the boundary between the two properties, and the set-in nature of the proposed infill extension, I find that the proposal would not have any serious adverse effect on the neighbours’ living conditions by way of light, outlook or sense of enclosure.

  6. Section 07

    Conclusion

    By virtue of its unobtrusive position, its complementary materials and design, and its limited scale, I find that the proposal would not be harmful to the character or appearance of the CA. Furthermore, by virtue of its set-in nature from the boundary, coupled with its limited height and depth, it would not be harmful to the living conditions of the occupiers of No [address] of light, outlook or sense of enclosure. On this basis it would not conflict with Policies CC2, CC4 and SC7 of the LP. Accordingly, I allow this appeal.

  7. Section 08

    Conditions

    I have attached a condition relating to plans because it is necessary that the development shall be carried out in accordance with the approved plans for the avoidance of doubt and in the interests of proper planning. I have attached a further condition relating to materials in the interests of the visual amenities of the area.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 239No official casework-database value to compare
    Extracted decision date · page 1
    30 December 2021Matches the official casework database
    Extracted site visit dates
    17 December 2021 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3282357
Application reference
00371/98/P2
Lead case reference
Not recorded
Planning authority
London Borough of Hounslow
Planning authority code
E09000018

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
4 m²
Number of residences
1
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Allowed
Decision category
Allowed
Received date
6 September 2021
Valid date
16 September 2021
Start date
9 November 2021
Planning authority decision date
28 June 2021
Appeal decision date
30 December 2021

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
8301
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:25
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21