Skip to main content
Official casework recordDismissedCurrent release

Appeal 3284671

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

8 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

air conditioning unit and wall mounted acoustic sound reduction enclosure (part retrospective).

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Procedural Matter

    The application is described as part retrospective. It is clear from my site visit and the evidence before me that the air conditioning unit has been constructed, but the wall mounted acoustic sound reduction enclosure has not. Accordingly, I have determined the appeal on this basis.

  3. Section 04

    [name]

    The main issues in the appeal are the effect of the proposals on: • the character and appearance of the host house and the streetscene. • the living conditions of the occupiers of No.[address], with particular regard outlook and noise.

  4. Section 05

    Character and appearance

    No. [site address] is a detached two-storey house of a contemporary style. The existing Air Conditioning Unit (ACU) is positioned on the right hand flank elevation of No.5 at a reasonably high level (around 3.2m) but toward the back of the house. It is of fairly modest proportions (0.9m x 0.9m x 0.5m) but is set off the flank elevation by a support bracket fixed to the wall. No.5 and its neighbour at No.[address] are very set close to their respective boundaries such that the gap between the two flank elevations is only just over 1m. The ACU is most readily seen when directly facing this gap from the street (above the side gate of No.5), but the close proximity of the flank elevations of the two houses and the set back means that the zone of visibility is actually very limited. I saw on my site visit that the ACU unit can be seen from the footway on either side of [address] but it is barely visible, and only for a short section as you walk in either direction. Views between No.5 and No.7 (and therefore the ACU) are also reduced by an existing tree within the footway. Whilst appearing somewhat utilitarian or commercial, the ACU would not be at all prominent in the streetscene and does not appear a particularly incongruous addition to the host house.

    The proposal is for a wall mounted acoustic reduction enclosure that would encase the existing ACU. This would increase the overall depth of the unit by around 150mm and height by around 300mm. Despite this modest increase in size, I am satisfied that the proposal would not substantively detract from the character and appearance of the host house and surrounding area.

    Consequently, on this main issue, I find no conflict with Policies SS1 and UD1 of the Watford Local Plan Part 1 – [name] 2006-31 (2013) (CS) which, amongst other things, seek to ensure high quality design that reflects local character.

  5. Section 06

    Living conditions

    The rear elevation of No.5 extends beyond that of its neighbour at No.[address] (No.7) and the location of the ACU to the rear of the property means that it is visible from the rear windows of No.7. This is confirmed in the [name] (AR) submitted on behalf of the appellant which describes the relationship in the following terms ‘the nearest non-associated residential window being rear aspect first-floor windows of [address], 2m from and with line of sight of the ACU next door at [site address] .’ Whilst the proposed louvred plant enclosure would improve the fairly commercial appearance of the ACU, it would increase its overall proportions and therein prominence when viewed from the rear of No.7, causing harm to outlook.

    I recognise that the existing ACU has been in its current position for a number of years and note the appellant’s comments that there has been no noise or disturbance or detriment to the amenities of surrounding residential properties to date. However, I am mindful that the absence of an objection, or objections, does not in itself confirm that there is no harm to the living conditions of neighbours arising from a development.

    The AR submitted with the planning application assessed the proposal against accepted [name] (BS) 4142 whereby the noise from a source is compared with the prevailing background noise. At a distance of 1m from the nearest noise sensitive window (the rear first-floor window of No.[address], only 2m away) the ACU noise was measured as being +24dBA above background levels. The appellant’s own AR concluded that the ACU ‘will therefore require significant noise attenuation in order to comply with the [name] and reduce the impact on neighbour amenity.’ I accept that the assessed increase (of +24dBA) represents a ‘worst case scenario’ based on the lowest background noise level. However, even if the average background noise level were to be taken, the increase would still be +18dBA. BS 4142 gives an indication of the impact of an increase in noise – a +10dBA increase represents a ‘significant adverse impact.’

    It is proposed to retain the existing ACU in its current position, but to enclose it with 150mm deep single bank acoustic louvres on three sides. I note that the advice in the AR is that it is unlikely that there is sufficient space in the current location (between No.5 and No.7) for the ACU unit to be re-housed in an enclosure capable of attenuating noise levels at or below background levels. Moreover, it advises that a minimum 300mm is typically required around the ACU to allow sufficient airflow and efficient operation. The acoustic enclosure detail submitted with the planning application (ref. 21059-PL-02-P2) shows only 50mm between the ACU and the acoustic louvres. So, well below this minimum. The AR assesses the effect of the proposed plant enclosure on noise levels. This shows that although there would be a reduction in noise associated with the ACU, it would still be +16dBA above the lowest background noise level. I therefore find that notwithstanding the proposed enclosure, the ACU would still have a significant adverse noise impact, such that it would cause harm to the living conditions of the neighbours at No.7.

    The proposal would therefore fail to accord with CS policy SS1 in so far as it seeks to secure well-designed development with regard to the amenity of neighbouring residents. It would further fail to accord with saved Policy SE22 of the Watford District Plan 2000 (2003) which seeks to ensure the separation of noise sensitive uses from sources of noise.

  6. Section 07

    Other matters

    I have noted the appellant’s comments regarding the clarity of information available for homeowners in relation to the installation of ACUs and whether planning permission is required, but this is beyond my consideration of the planning merits of the proposal before me.

  7. Section 08

    Conclusions

    Notwithstanding my conclusions with regard to character and appearance, I have found significant harm to the living conditions of the neighbours of No.[address] with regard outlook and noise. Therefore, for the reasons given above, the appeal is dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 114No official casework-database value to compare
    Extracted decision date · page 1
    31 January 2022Matches the official casework database
    Extracted site visit dates
    7 January 2022 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3284671
Application reference
21/01158/FULH
Lead case reference
Not recorded
Planning authority
Watford Borough Council
Planning authority code
E07000103

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
12 October 2021
Valid date
12 October 2021
Start date
15 November 2021
Planning authority decision date
23 September 2021
Appeal decision date
31 January 2022

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
No
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
9703
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:25
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21