Appeal 3308831
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
5 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
single storey rear extension and new dormer to rear.
Section 02
Decision
The appeal is dismissed, insofar as it relates to the new dormer to rear.
The appeal is allowed, and planning permission is granted, insofar as it relates to the single storey rear extension, at [site address] in accordance with the terms of the application, Ref 22/04081/FU, dated 10 June 2022, subject to the following conditions:
The development hereby permitted shall begin not later than 3 years from the date of this decision.
The development hereby permitted shall be carried out in accordance with the following approved plans insofar as they relate to the allowed matter: [name]: 22-001-01; 22-001-02A; 22-001-03; 22-001-04; 22-001-05; 22-001-06; 22-001-07; 22-001-08; 22-001-09A; 22-001-10; 22-001-11 A.
The materials to be used in the external surfaces of that part of the development hereby permitted shall match those used in the existing building.
Section 03
Main Issue
The main issue is whether the proposed development would preserve or enhance the character or appearance of the [site address] Conservation Area (CA).
Section 04
Reasons
The appeal property is located within an area of twentieth century housing within the CA. The CA covers a large area with the suburban housing along [address] contrasting with both the historical buildings within the core of the CA and its more rural parts. The Council’s CA Appraisal and Management Plan (2009) (CAA) sets out that the key characteristics of the twentieth century suburban housing lies in its discreteness. From my observations on site, I agree.
The proposed dormer would occupy a large proportion of the depth and width of the rear roof slope of the property. It would have a box like form, giving it a stark and discordant appearance on the roof. The appeal site is near the junction of [address] and [address], which is a prominent focal point within the CA. Here, the proposed dormer would be visible in gaps between buildings around [name] and the [name]. The bulky nature of the dormer would erode the discreteness of the host property. As a result, it would harm the character and appearance of the CA.
The appellant has provided details of other large bulky dormers, which the Council have approved in [address] (the Close) (No 60 and No 47). I do not have full details of the circumstances that led to these dormers being approved by the Council. However, these are isolated instances within the Close, and most of the roof slopes remain uninterrupted by such dormers. The absence of such dormers helps, in my view, to preserve the discrete qualities of the twentieth century housing. Nonetheless, I accept there are similarities in their design and positioning on the roof slope.
The dormer approved at No 60 would be highly visible from the Close but it would be seen within the context of the surrounding suburban twentieth century housing. The dormer at No 47 would be visible from the grounds of [name], and the footway adjacent to it. However, any views would be of the side profile rather than the full rear façade. In this instance, the rear of the roof slope of the appeal property is visible from beyond the suburban twentieth century housing, and around a focal point of the village. As such, I do not consider that the approved dormers, at No 60 and No 47, should set a precedent for the appeal proposal.
The proposed single storey extension would wrap around the rear and side, but it would be stepped back significantly from the front façade. Moreover, its modest height, depth and matching materials would ensure that it would be a sympathetic addition that would preserve the character and appearance of the host property and surrounding CA.
To conclude on the main issue, the proposed single storey extension would preserve the character or appearance of the CA. However, the dormer roof to the rear elevation would not preserve the character or appearance of the CA.
The harm to the CA from the dormer would be localised and, as such, would be less than substantial in the context of paragraph 202 of the National Planning Policy Framework (the Framework). In accordance with paragraph 202 I must balance that less than substantial harm against the public benefits of the proposal. This classification of harm does not mean that it is diminished though. The Framework identifies that great weight should be given to designated assets’ conservation, the weight increasing the more important the asset. Therefore, although the harm to the overall CA would be very small, this carries great weight and remains of considerable importance.
The appellant is seeking to improve the property and the proposed dormer would improve the living conditions associated with it. Moreover, it would not harm the living conditions of the occupiers of any neighbouring property. However, the overall benefits to the public would be limited. As such, the benefits, and the lack of harm to other considerations, do not outweigh the great weight given to the harm to the character and appearance of the CA from the proposed dormer.
To conclude, the proposed single storey rear extension would not conflict with the requirements of Policies P10, P11 and P12 of the Council’s Core Strategy (CS) (2019), Policies GP5 and BD6 of the Council’s Unitary Development Plan (UDP) (2006), Policy HDG1 of the Householder Design Guide Supplementary Planning Document (SPD) (2012) and the provisions of the Framework, when taken together.
However, the proposed new dormer to the rear would conflict with Policies P10, P11 and P12 of the CS, Policies GP5 and BD6 of the UDP, Policy HDG1 of the SPD and the provisions of the Framework, when taken together. These say, amongst other things, that the historic environment, consisting of archaeological remains, historic buildings townscapes and landscapes, including locally significant undesignated assets and their settings, will be conserved and enhanced, particularly those elements which help to give Leeds its distinct identity.
Section 05
Conclusion and conditions
The proposed single storey rear extension is clearly severable, both physically and functionally, from the proposed new dormer to the rear.
Accordingly, for the reasons given above, the appeal is allowed insofar as it relates to the proposed single storey rear extension. However, the appeal is dismissed insofar as it relates to the proposed new dormer to the rear.
In respect of the allowed elements, I have attached the standard time limit condition (1) and a plans condition (2) as this provides certainty. I have also included a condition (3) requiring the materials match the host property in the interests of the character and appearance of the CA.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 1160No official casework-database value to compare
- Extracted decision date · page 1
- 7 March 2023Matches the official casework database
- Extracted site visit dates
- 15 February 2023 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3308831
- Application reference
- 22/04081/FU
- Lead case reference
- Not recorded
- Planning authority
- Leeds City Council
- Planning authority code
- E08000035
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- 24 m²
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Split Decision
- Decision category
- Split decision
- Received date
- 12 October 2022
- Valid date
- 12 October 2022
- Start date
- 25 October 2022
- Planning authority decision date
- 9 August 2022
- Appeal decision date
- 7 March 2023
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 29399
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:26
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21