Appeal 3311682
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
8 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
Single storey rear extension 6m deep x 3m high (3m high to eaves).
Section 02
Decision
The appeal is dismissed.
Section 03
Preliminary Matters
The proposed development is described on the application form as single storey rear extension 6m deep x 3m high (3m high to eaves). The existing and proposed plans confirm the proposed development would include two single storey rear projections, which are not attached to each other. I sought clarification from the appellant in relation to whether the proposal sought prior approval for both extensions, the appellant has confirmed that both elements are included, and the description is for the maximum depths and heights of the proposed elements. The Council have considered the application on this basis, and I have dealt with it in the same way.
Article 3(1) and Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) (GPDO) grants planning permission for the enlargement of a dwellinghouse subject to limitations and conditions.
Where an application is made for a determination as to whether prior approval is required for development which exceeds the limits in paragraph A.1(f) but is allowed by paragraph A.1(g) to Part 1(larger home extension), paragraph A.4(3) provides that the local planning authority may refuse the application where it considers that the proposed development does not comply, or that the developer has provided insufficient information to enable the authority to establish whether the proposed development complies with the conditions, limitations or restrictions that are applicable to such permitted development.
[name].4(7) to Part 1 of the GPDO also requires the local planning authority to assess the impact of the proposed development on the amenity of all adjoining premises, taking into account any representations received.
Whilst not referred to in the refusal reason, the decision notice advises that the proposed extensions exceed the GPDO limits. Representations were also received in connection with the proposal from the adjacent property occupiers raising objections to the proposals on the grounds that the proposed extension would result in a loss of outlook from, and overshadowing to, their property. The letter also makes representations in respect of the character and appearance of the area and the impact upon drains. However, these are not matters that fall within the scope of consideration in respect of an application for prior approval.
Section 04
[name]
The main issues are whether the proposed development would be granted planning permission by Article 3, Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) (the GPDO) and the effect of the proposed development on the living conditions of adjoining premises with regard to light and outlook.
Section 05
Whether permitted development
No [site address] (No 26) is a substantial semi-detached property. There is an existing two storey rear outrigger, and the rear of the original building is stepped. The Permitted Development Rights for Householders: Technical Guidance (the Technical Guidance), September 2019, advises that where the original rear wall of a house is stepped, then each of these walls will form the rear wall, and also side wall. Both extensions extend from the rear walls and are separated by a gap.
The Council has not referred to any relevant sections of the GPDO, nor the Technical Guidance. Their evidence infers that proposals submitted under the prior approval larger home extension scheme, can include a single 6 metre extension, or several 3 metre extensions, but not two which would amount to a combined depth of 9.49 metres.
This proposal shows two separate elements on different parts of the house. Their lengths would not be combined to make a 9.49m extension. Had that approach been intended, then the diagram on page 19 of the Technical Guidance showing three separate extensions of 3 metres would also not be permitted development.
The internal arrangement clearly shows a layout which would keep the living accommodation/playroom separate from the dining and kitchen accommodation. The gap between the extensions would be sufficient to ensure that the extensions would not be construed as a single entity. The proposed development does not extend beyond, nor are the extensions attached to a side wall. Neither do they entirely fill the area between a side elevation and a rear wall.
As such I have assessed each of the enlarged parts of the dwelling house against the conditions for extensions beyond a rear wall. The proposed extensions would be constructed from the original rear elevations. At no point would the extensions breach 6 metres from the rear of the property.
Therefore, the proposal would satisfy the relevant requirements in the associated paragraphs contained in A.1 On the basis of the evidence before me, the proposed development would satisfy the criteria to be permitted development, under the terms of Schedule 2, Part 1, Class A.1 of the GPDO.
Section 06
Living Conditions
The appeal property is attached to No [address] (No 24). Whilst not shown on the submitted Block and Location plan, No 24 has been extended to the rear. The dwelling has glazed doors on the rear of the property, where the building is recessed, which is sited close to the joint boundary with the appeal site. This opens out onto the garden area. The shared boundary treatment is lower than the rear windows and in parts consists of open lattice panels, which does not provide full screening, and allows sunlight and daylight to the rear of the property and garden area.
Policies CP30 of the [name] (the Core strategy) 2010, and Policies DMD8, DMD11 and DMD37 of the Enfield Development Management Document (DMD) 2014 require a high quality and design led approach having special regard to its context and neighbouring residents living conditions. Policy DMD11 of the DMD specifically states that single storey extensions must not exceed 3 metres in depth beyond the original wall of semi-detached properties, 3 metres in height, nor exceed a 45-degree line from the mid-point of neighbouring windows. The justification advises this distance is required for amenity and is to avoid overshadowing and loss of privacy.
The plans before me show that the proposal would extend more than 3 metres beyond the rear of No 24, immediately along the shared boundary. However, even with the extension at No 24, this would exceed the 45-degree angle contained in Policy DMD11. Although the proposals have a flat roof, the larger extension would project significantly above the lower open shared boundary fence. The higher, longer, more permanent and solid structure would be very visible within the property and garden. The proposal would create a tunnel effect on that property due to built development flanking both sides of the window and garden in the recessed area, which is likely to be well used given that it provides access. I find that the above factors would result in a harmful sense of enclosure, detrimental to the outlook from the doors and garden area of No 24.
Although the appellant has provided a daylight/sunlight analysis, at my site visit at 2pm on a sunny day, I could see that existing boundary treatment cast a shadow. Similarly given the height and orientation of the extension relative to No 24, the proposed development would do the same. Although the proposal may not result in a discernible effect to the fenestration of the adjoining property, in my view the shadow to the garden area would ultimately make it a less attractive area to spend time, and although a limited effect it would add to the harm identified above.
The adjacent property at No [address] is detached from the appeal dwelling and there is a passageway width between them both, with close boarded fencing along the joint boundary. No 28 also has a rear outrigger with windows serving living accommodation. The main outlook from the rear windows of No 28 is directly to the rear of the property. The extension would be visible in peripheral views, but only above the higher fence. Although it would also be visible from the rear garden the space afforded by the gap between the dwellings, the overall position of the proposed extension relevant to the neighbouring windows, height of fence and orientation reduces the effect upon this property. Furthermore, although it would exceed the distance in Policy DMD11, the Council has identified it would not breach the 45-degree angle to the adjacent window.
I note the Council did not find harm in respect of the adjoining neighbouring property or garden at No [address] (No 1). I concur with this assessment as the garden length and site boundaries would prevent overlooking, and overbearing effects on this and other neighbouring gardens and properties.
The proposed development would not cause harm to the living conditions of No 28, and No 1, but this does not outweigh the harm to No 24. I conclude that the proposal would have a harmful effect on the living conditions of No 24 in terms of outlook.
Section 07
Other Matters
Although it is understood that the Council did not consider the daylight and sunlight assessment, for the reasons set out above, I have found harm irrespective of this.
Section 08
Conclusion
For the reasons given, the appeal is dismissed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted decision date · page 1
- 29 August 2023Matches the official casework database
- Extracted site visit dates
- 3 May 2023 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3311682
- Application reference
- 22/02742/PRH
- Lead case reference
- Not recorded
- Planning authority
- London Borough of Enfield
- Planning authority code
- E09000010
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 3. Refused prior approval of permitted development rights
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 1
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 22 November 2022
- Valid date
- 22 November 2022
- Start date
- 18 January 2023
- Planning authority decision date
- 27 September 2022
- Appeal decision date
- 29 August 2023
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 37750
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:27
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21