Skip to main content
Official casework recordDismissedCurrent release

Appeal 3317930

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

4 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

described as a single storey side return extension including 2X skylights on the roof.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Main Issue

    The main issue is the effect of the proposal on the living conditions of the occupiers of [address] (No.18), with particular regard to visual impact, daylight and sunlight.

  3. Section 04

    Reasons

    The Appeal property Comprises a traditional two storey inner terraced house with a two-storey rear wing. There is a similar rear projecting wing at No.18 and narrow gaps between the wings and the boundary wall between the two properties. Within the rear projecting wing at No.18 are two ground floor windows that face directly towards the appeal dwelling and a further window within the recessed rear wall of the dwelling, which faces the rear garden.

    Policy LP8 of the London Borough of Richmond Upon Thames Local Plan 2018 (LP) states that development must protect the living conditions of the occupiers of adjoining buildings. Amongst other things the design of new development must enable good daylight and sunlight standards. They should not be visually intrusive or overbearing as a result of their height, massing, siting or sense of enclosure. The supporting text to this policy explains that the aim is to protect the living conditions and amenities of the occupiers of existing properties from unreasonable harm. Adverse impacts can include perceived loss of light, sense of enclosure, or through overpowering, overbearing or obtrusive development.

    The London Borough of Richmond Upon Thames Supplementary Planning Document – [name] and [name] 2015 (SPD), is consistent with this. It advises that extensions should not create an unacceptable sense of enclosure or appear overbearing when viewed from neighbouring properties. Also, that three metre deep rear extensions to terraced houses are usually acceptable and there is some flexibility regarding deeper extensions depending on the circumstances on the site. Where rear infill extensions exceed three metres in depth it advises that the eaves height of the extension should not exceed 2.2 metres in height. This is to mitigate any sense of enclosure.

    The National planning Policy Framework (the Framework) promotes a proactive approach to planning and the effective use of urban land. Paragraph 130 states that new development should function well and add to the overall quality of the area and be visually attractive. Development should optimise the potential of the site and create places that are safe, inclusive, accessible and which promote health and well-being, with a high standard of amenity for existing and future users.

    As indicated above, in principle the council does not object to rear infill extensions, subject to compliance with other policies set out in the development plan and associated guidance. The proposed rear side return extension would be subservient to and would respect the proportions and roof detailing of the existing rear projecting wing. Whilst the proposed wide bi-folding doors would change the appearance of the rear elevation, the overall proposal would respect the character and appearance of the host dwelling. In these respects, the proposal complies with the above policies and guidance.

    However, the proposed extension would project up to the boundary with No.18 and 5.5 metres beyond the recessed rear building line of both dwellings. It would have a mono-pitched roof that would be 2.78 metres height where it adjoins the boundary with No.18, rising to approximately 3.7 metres where it adjoins the existing rear projecting wing.

    The existing boundary wall between the two properties is less than two metres in height, with timber trellising and some soft planting above it. The wall creates a sense of enclosure in the outlook from the adjacent side and rear facing windows. Conversely, the trellis and planting allow views through them and for daylight and sunlight to filter through. As a consequence, their contribution to the existing sense of enclosure is minimal and is not comparable to that of the side wall and roof of the proposed extension.

    Taking these factors into account I find that, due to its combined height, depth and proximity, the proposed extension would have an enclosing and oppressive impact on the outlook from the two adjacent windows in the rear projection at No.18. It would also create an enclosing and oppressive tunnel effect in the outlook from the adjacent rear facing ground floor window at No.18. Overall. the proposal would have an oppressive and overbearing impact, which would unacceptably harm the living conditions of the occupiers of No.18.

    Although it is noted that the rear of the dwelling at No.18 has a southerly aspect, due to its combined height, depth and siting to the west, the proposed extension would result in the loss of some daylight along with some sunlight in the afternoons. Whilst such loss would be modest and would not amount to a reason for dismissing this appeal, it would exacerbate the oppressive and overbearing nature of the proposal.

    Overall, the harm that would be caused to the living conditions of the occupiers of No.18 would materially outweigh the benefits for the appellant and their family that would result from the proposed additional accommodation. Further, due to the nature of the concerns it is not a matter that could be satisfactorily dealt with by condition.

    Finally, the appellant has referred to a number of rear return extensions that have been allowed. However, as no drawings or dimensions for these extensions have been provided, it is not possible to compare them to the appeal proposal. Irrespective of this, paragraph 47 of the Framework points out that planning law requires that planning applications be determined in accordance with the development plan, unless there are material considerations that dictate otherwise. The appeal has been determined on this basis and in this instance, I find that the proposal would be unacceptable for the reasons set out above.

    I conclude that the proposal would unacceptably harm the living conditions of the occupiers of No.18. Accordingly, it would conflict with LP Policy LP8, the SPD and paragraph 130 of the Framework.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 1220No official casework-database value to compare
    Extracted site visit dates
    2 August 2023 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3317930
Application reference
22/2744/HOT
Lead case reference
Not recorded
Planning authority
Richmond Upon Thames London Borough Council
Planning authority code
E09000027

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Unknown
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
6 March 2023
Valid date
14 April 2023
Start date
3 July 2023
Planning authority decision date
12 December 2022
Appeal decision date
15 August 2023

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
37161
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:27
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21