Appeal 3320455

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

8 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

first floor rear bedroom extension.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Preliminary Matters

    I have taken the description of development from the application form. Although different to that on the decision notice, no confirmation that a change was agreed has been provided.

    Planning permission has recently been granted at the appeal site for extensions and alterations to the dwelling1. The plans submitted with this appeal include details of the approved scheme, although it was apparent that the approved scheme had not been implemented at the time of my site visit. For the avoidance of doubt, this appeal relates only to a proposed first floor extension at the rear of the property, and I have determined the appeal on this basis.

    The Appellant has submitted an amended plan with the appeal which shows revised proposed west (side) and south (rear) elevations. This change relates to a substance of concern expressed by the Council. Procedural guidance2 states that the appeal process should not be used to evolve proposals and is clear that revisions intended to overcome reasons for refusal should normally be tested through a fresh application. It is important that what is considered by the Inspector is essentially what was considered by the local planning authority, and on which interested people’s views were sought. I have had regard to the Wheatcroft Principles3 and conclude that it would not be fair or reasonable to determine the appeal against the amended plan, as to do so would prejudice interested parties. I have therefore determined the appeal on the basis of the plans that were before the Council when it made its decision and on which parties were consulted. 1 [name]:P/4439/21 2 Procedural Guide to Planning Appeals - England (2016) 3 Wheatcroft (Bernard) Ltd v Secretary of State for the Environment [1982] JPL 37

  3. Section 04

    [name]

    The main issues are the effect of the proposal on: • The character and appearance of the host building and the area; and • The living conditions of the occupiers of Nos. 61 and [address], with particular regard to outlook.

  4. Section 05

    Character and appearance

    The appeal property is an extended two-storey detached dwelling located within a residential area on a gently sloping street. The first-floor rear elevation and roof slope of the dwelling, and neighbouring properties are clearly visible from [address] close to its junction with Southfield Park.

    The surrounding area is characterised by predominantly two storey semi-detached and occasional detached dwellings with rear gardens and set back from the road behind short driveways or gardens. Whilst the appearance of dwellings varies, there is a general consistency of height and proportions to dwellings in the area.

    The proposed extension would extend above the existing flat roof ground floor extension at the rear of the appeal property. It would have a hipped roof that, at its highest point, would reach the bottom of the rear dormer of the approved scheme. The first-floor plan indicates that the proposed extension would be set in from the side elevations of the property. However, the proposed attic, rear and side elevation plans indicate that the rear roof slope would extend either side of the proposed extension to meet its rearward projection. This would result in differing first floor eaves heights and no step-in from the main side elevations of the property.

    [name] have not been provided with a copy in respect of this appeal, I am aware from the submissions and from determining other appeals in the area, that the Harrow Supplementary Planning Document: [name] 2010 (SPD) advises that extensions should harmonise with the scale and architectural style of the original building, and the character of the area.

    The proposal would be modest in scale. However, it would project rearward at first floor with a built form that would present as an awkwardly designed and conspicuous enlargement. Given the resultant combination of various eaves heights and roof forms that would be noticeable on this elevation, the proposal would be an incongruous form of development.

    Furthermore, due to the substantial gap along [address] from No. [address] to the rear elevation of properties along Southfield Park, the proposed development would be clearly visible. From here, with or without the approved rear dormer, the inharmonious form of the proposal would be exacerbated by its projection forward of the general first floor building line of the rear of other properties along this part of Southfield Park. As a result, it would be visibly at odds with, and diminish the prevailing character of the property and the area.

    For the above reasons, I conclude that the proposal would have an unacceptably harmful effect on the character and appearance of the host building and the area. As such it would conflict with Policies D3 (D(1) and D(11)) of The London Plan, March 2021 (LP); Policy CS1.B of the [name], February 2012 (HCS) and Policy DM1 of the Harrow Development Management Policies, July 2013 (HDMP). Together, these policies, amongst other things, seek development that respects the host building, achieves a high standard of design and that responds positively to local character. It would also not accord with guidance contained within the SPD or the objectives of the National Planning Policy Framework (the Framework) which seek similar aims.

  5. Section 06

    Living conditions

    The adjacent property at No.[address] (No.61) is a detached two storey dwelling. At my site visit, I observed that the existing first floor rear elevation of No.63 projects slightly beyond the first-floor rear elevation of No.61 and I note inconsistencies with the submitted plans in this regard, which indicate the two properties are in line at rear first floor level. Notwithstanding this inconsistency, the proposed extension would project even further beyond the rear first floor of No.61.

    The Council’s SPD indicates that a 45-degree code should be applied for proposed extension to avoid an overbearing impact on neighbouring residents. However, the SPD also states that the code should not simply be applied on a mechanical basis but as part of an assessment of several site considerations.

    While the proposal would contravene the 45-degree splay when account is taken of the continuing roof slope at the rear, the closest rear facing window of No.61 to the proposal is set in from the corner of the building and the height of the proposed catslide roof would be relatively low. The combination of the gap between the two dwellings and the distance between the closest rear facing window at No.61 and the proposed extension, would mean that the proposal would not present a significantly overbearing or poor outlook for occupiers of No.61.

    Furthermore, the rear elevation of No.61 faces south-east and there are long rear gardens to the rear which provide considerable outlook for occupiers of the property.

    No.[address] (No.65) is a two-storey semi-detached dwelling adjoining the appeal property. It has a two-storey side extension close to the common boundary with No.63 and includes a first-floor rear facing window. However, the proposed extension would not project significantly beyond the existing rear first floor of No.65 and a gap would be maintained between the two dwellings. For the same reasons as above, while the proposed catslide roof would marginally contravene the 45-degree splay, the closest rear facing first floor window at No.65 is set in from the corner of the dwelling and the height of the proposed catslide roof would be relatively low. Accordingly, the proposal would not harm the outlook for occupiers of No.65.

    For the reasons given above, I conclude that the proposal would not have an unacceptably harmful effect on the living conditions of the occupiers of Nos. 61 and [address], with particular regard to outlook. I therefore find no conflict with Policy D3 (D(7)) of the LP, Policy CS.1B of the HCS and Policy DM1 of the HDMP which together, amongst other matters, seek development that has an appropriate spacing and outlook for neighbouring residents. There would also be no conflict with the SPD given the apparent flexibility afforded when assessing house extensions in relation to outlook, or the high standard of amenity objective of the Framework.

  6. Section 07

    Other Matters

    Although there were no objections to the proposed development, a lack of objection is not a reason to approve unacceptable development.

    I acknowledge that the proposal was amended in response to previous planning refusals4. However, the reasons for the eventual officer recommendation and decision are clearly set out in the [name] and communications prior to that point do not have a bearing on my consideration of the main issues, as set out above.

  7. Section 08

    Conclusion

    [name] find no harm to the living conditions of the occupiers of Nos. 61 and [address], with particular regard to outlook, the proposal would harm the character and appearance of the host building and the area. Accordingly, the proposal would conflict with the development plan, when taken as a whole. There are no other considerations, including the Framework, that indicate that I should take a different decision other than in accordance with the development plan.

    Therefore, for the reasons given above, I conclude that the appeal should be dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 3983No official casework-database value to compare
    Extracted decision date · page 1
    28 November 2023Matches the official casework database
    Extracted site visit dates
    7 November 2023 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3320455
Application reference
P/4399/22
Lead case reference
Not recorded
Planning authority
London Borough of Harrow
Planning authority code
E09000015

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Unknown
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
13 m²
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
17 April 2023
Valid date
19 April 2023
Start date
13 June 2023
Planning authority decision date
23 February 2023
Appeal decision date
28 November 2023

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
No
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
42687
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:27
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21