Appeal 3320964
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
9 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
Single storey and first floor rear extensions to address as built details relating to eaves and ridge heights being higher than approved by 600mm.
Section 02
Decision
The appeal is allowed, and planning permission is granted for single storey and first floor rear extensions to address details relating to eaves and ridge heights being higher than approved by 600mm in accordance with the terms of the application Ref 23/0109, dated 1 January 2023, subject to the following
Section 03
condition.
The development hereby permitted shall be carried out in accordance with the approved plans drawing nos. 2323-02-02 and 2023-02-03.
Section 04
Preliminary Matters
The description of development above is taken from the application form, but I have removed the reference to resubmission of a previous application as it is not a definition of development.
The Council and a third party have drawn my attention to a number of discrepancies between the submitted plans intended to show what has been built, and what has actually been built on site. Between them these include the eaves of the first-floor extension being even taller than shown; the first and ground floor extensions being built closer to, and possibly on, the boundary with No.152, and the guttering for the extensions overhanging the neighbour’s property – the plans show the guttering within the boundary line drawn down from the chimney.
These differences are not before me as part of this appeal, as I am required to consider and determine the appeal development based on the submitted plans which were before the Council when it made its decision, and which are the subject of this appeal. The Council can choose to avail upon its enforcement powers if development has taken place beyond the scope of this permission should it deem it expedient to do so. Determining the position of the boundary is a civil matter between the parties.
Section 05
Background and [name]
The Council granted planning permission1 for single storey and first floor rear extensions (the ‘approved scheme’). However, the rear single storey extension, with its dual pitched roof and small section of flat roof, has not been built in accordance with the plans and the extension has been built taller. A new application, the subject of this appeal, was submitted to address the retrospective development.
The Council’s concerns lie with the single storey rear extension and therefore I too have confined my assessment to the single-storey rear extension.
The main issues in this appeal are: • The effect of the single storey extension on the living conditions of occupiers of [address] (No.152) with regards to light and outlook, and • The effect of the single storey extension on the character and appearance of the area.
Section 06
Living conditions
The appeal site comprises the middle property of a terrace of three dwellings in a predominantly residential area. The adjoining properties, Nos.152 and 156, each have their own single storey rear extensions. The single storey rear extension at the appeal property would extend beyond the end of these existing rear extensions by about 3.7 metres, as annotated on the approved plans.
However, the extension at the appeal property is now taller. I am advised that the height to eaves level and ridge level of the pitched roof part of the extension has been increased by about 600mm, and the height of the flat roof extension has increased by about 400mm. As a result, the amount of development along the shared boundary with the neighbouring property has increased and I need to determine whether, as a result, there would be an unacceptable loss of light or outlook.
The ‘45-degree code’ is a guideline commonly used by Councils to help ensure that extensions do not have a detrimental impact on neighbouring properties with regard to daylight and sunlight by avoiding unacceptable levels of overshadowing.
The Council confirms that under the ‘approved scheme’ the single storey extension would breach the 45-degree code by approximately 1 brick’s depth, but this was not considered to have a significant effect due to the then proposed height of the extension. The Council calculated that the extension, or indeed any extension, would affect full access to natural sunlight and create some degree of overshadowing for occupiers of No.152.
The Council’s sunlight re-assessment for the taller extension lists the lengths of shadows at different times of the year and day. At its worst the shadows would be about 2.4 metres longer when the sun is at its highest position directly 1 Local Planning Authority ref: 20/1517 granted 16 November 2021 south in the sky on 21 December2. Hence there would be a greater overshadowing as a result of the taller extension.
I saw that No.152 has a small window in its rear extension closest to the appellant’s extension. This looked to serve a toilet or utility room and not a habitable room, hence the effect on light to such rooms is deemed negligible. There was a larger window and half-glazed back door about mid-way along the neighbour’s extension that did appear to serve a habitable room so there would likely be some further loss of light and overshadowing to this room. However, considering the amount of height increase any reduction in light levels would not be significant.
The extension would be about 600 mm taller to eaves level, but the roof slopes away from the neighbour’s boundary and the extension is not shown longer than the approved scheme. As a result, the outlook for occupiers of No.152 from this rear room would not be significantly different compared to the situation that was allowed in the approved scheme. I also saw that No.152 is not significantly enclosed and has a good-sized garden with an open aspect such that uninterrupted views over their own garden would remain, maintaining adequate outlook and light.
Taking these factors into consideration, I am satisfied that any further loss of light resulting from the taller single storey extension would not be significant. Furthermore, the extension would not be unduly overbearing, oppressive or enclosing. Therefore, the single storey extension would not harm the living conditions of the occupiers No.152 with regards to light and outlook.
Accordingly, it would not be contrary to ‘saved’ Policies GP2 of the Unitary Development Plan (the UDP) that seeks to ensure, amongst other things, that new development takes account of the effect on light received by neighbouring properties. There would be no conflict with [name] of the Council’s Designing Walsall Supplementary Planning Documents (the [name]) relating to the 45-degree code and effect on amenity.
Section 07
Character and appearance
The Council has already approved the size of the footprint of the extension and allowed a wide dual-pitched roof across the width of the property. The approved scheme had a shallower roof, with the apex of the roof set some distance below the first-floor window cills. As a result of raising the height of the roof, the apex of the roof is now a small distance above the first-floor window cills.
I saw that there were a variety of extensions at the rear of some nearby properties, including conservatories and first floor extensions. The properties either side of the appeal property in the terrace each has a different design of single storey extension - No.152 has a mono-pitched roof extension that extends up to just below the first-floor window cills and No.156 has a flat roof rear extension which is lower. I also saw a wrap-around extension at a property next door-but-one where the roof of the extension extended to a similar height as the appeal development, but the roof had been cut away so as not to obscure the rear elevation windows. As it rounded the corner of the 2 December 21 is the day with the fewest hours of daylight in the year in the northern hemisphere, often referred to as the shortest day. property the height of the extension increased. Therefore, there is no prevailing design or style of extension or relationship with the host properties.
Furthermore, the extension and roof form are not an uncommon design for residential properties. The increase in height does not significantly alter the form of the roof of the extension, as it remains dual-pitched albeit a little steeper and taller. With the variety of extensions and roofs on the terrace within which the appeal property sits and in the immediate vicinity, the extension would not create a form of development that is unduly out of scale or character with the area, or with what has already been approved.
Accordingly, the appeal development would not conflict with ‘saved’ [name] GP2 and ENV32 that seek to ensure, amongst other things, that development takes account of its surroundings and its visual relationship with the street and character of the surrounding area. It would not conflict with Policy DW3 of the [name] that expects new development to be informed by the surrounding character.
Section 08
Conditions
As there appear to be differences between what has been applied for and what has been built, and I am only considering the development shown on the submitted plans, it is necessary for me to impose a condition to require the development is completed in accordance with the submitted plans.
Section 09
Conclusion
For the reasons given above I conclude that the appeal should be allowed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 320No official casework-database value to compare
- Extracted decision date · page 1
- 3 August 2023Matches the official casework database
- Extracted site visit dates
- 18 July 2023 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3320964
- Application reference
- 23/0109
- Lead case reference
- Not recorded
- Planning authority
- Walsall Metropolitan Borough Council
- Planning authority code
- E08000030
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- 31 m²
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- No
- Relates to a conservation area
- No
- Flooding is an issue
- No
- Site within an AONB
- No
- Site within an SSSI
- No
Decision and dates
The published outcome and every imported case date.
- Official decision
- Allowed
- Decision category
- Allowed
- Received date
- 25 April 2023
- Valid date
- 25 April 2023
- Start date
- 23 May 2023
- Planning authority decision date
- 31 March 2023
- Appeal decision date
- 3 August 2023
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- No
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 36619
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:27
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21