Skip to main content
Official casework recordAllowedCurrent release

Appeal 3323083

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

7 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

ground floor rear elevation extension.

  1. Section 02

    Decision

    The appeal is allowed and planning permission is granted for a ground floor rear elevation extension at [site address] , Feltham, Hounslow, [postcode] in accordance with the terms of the application, Ref 00207/38/P2, dated 23 March 2023, subject to the following conditions:

    The development hereby permitted shall begin not later than 3 years from the date of this decision.

    The development hereby permitted shall be carried out in accordance with the following approved plans: Location Plan; PP/20/23/01; PP/20/23/02; PP/20/23/03; PP/20/23/04 and the Fire Safety Plan - ‘Means of Escape’ and [name]

    The materials to be used in the construction of the external surfaces of the development hereby permitted shall match those used in the existing building.

  2. Section 03

    [name]

    The main issues are: • The effect of the proposal on the character and appearance of the host property and surrounding area; and • The effect of the proposal on the living conditions of the occupiers of [address].

  3. Section 04

    Character and appearance

    The appeal property is a two-storey, semi-detached dwelling located in a road comprising of similar properties.

    Policies CC1 and CC2 of the London Borough of Hounslow Local Plan 2015-2030 (2015) (LP) expect proposals (amongst other things) to respond to the context and character of the area in terms of design, whilst Policy SC7 requires residential alterations to complement the original building and harmonise with adjoining properties.

    The Council’s Residential Extensions Guidelines Supplementary Planning Document (2017) (SPD) whilst non-statutory, provides useful design guidance. The SPD states that single storey rear extensions should be secondary to the main house and should not project too far from the rear wall of the original house. It sets out a maximum depth of 3.65m for single storey rear extensions to semi-detached houses. It advises that the height of the extension should appear in scale with and subservient to the host dwelling and also confirms that a flat roof is normally acceptable for single storey rear extensions.

    The rear wall of the existing dwelling is staggered, which is a feature repeated on the adjoining semi, [address]. The proposed extension would similarly be stepped and would extend between 3.65m – 4.5m beyond the recessed element and about 3.7m beyond the other main rear wall. Depending on where the depth of the extension is measured from, it would exceed the depth of extension suggested as being appropriate in the SPD.

    The proposed extension would have a height of around 3m and would sit well below the first floor windows as required by the SPD. It would have a flat roof design which the SPD confirms is normally acceptable on single storey rear extensions. I saw on my site visit that several other dwellings in the immediate vicinity of the site have been extended to the rear in a similar manner.

    In my view the proposed extension would appear secondary and subservient to the main house as required by the SPD. Furthermore, it would be of a design and appearance that respects that of the host dwelling and other extensions that have taken place in the surrounding area.

    In conclusion of this main issue, despite some conflict with the guidance provided within the SPD in terms of its depth, I find that the proposal would not have a harmful effect on the character and appearance of the host dwelling or the surrounding area. Accordingly, it would comply with the design objectives of Policies CC1, CC2 and SC7 of the LP.

  4. Section 05

    Living conditions

    The wall of the proposed extension along the boundary with [address] would extend for a depth of 3.65m in line with the advice contained within the SPD. It would then step in from the boundary by about 1m and extend approximately a further 0.85m into the site.

    The closest opening to the boundary on the ground floor of No 40 is a glazed glass panel and patio doors. There is a double fence line along this part of the side boundary of the site, with a maximum height of about 1.8m. The proposed extension, with a height of around 3m at the eaves, would therefore extend above the fence.

    However, the design of the extension ensures that the length of wall along the boundary would not exceed 3.65m as set out in the SPD. The remainder of the extension would be set in from the boundary by about 1m and given its limited additional depth and relative low height, I do not consider that the extension would be unduly prominent or visually intrusive when viewed from No 40 and would not lead to any significant loss of light to rooms within the house or its rear garden area.

    I therefore conclude on this issue that the proposal would not have a harmful effect on the living conditions of the occupiers of [address]. I therefore find that it complies with Policies CC2 and SC7 of the LP insofar as these policies seek to protect the living conditions of adjoining occupiers.

  5. Section 06

    Conditions

    In addition to the standard implementation condition, the approved plans condition is imposed for certainty. A condition requiring the use of matching materials is necessary to protect the character and appearance of the dwelling and the local area.

  6. Section 07

    Conclusion

    For the above reasons, and having regard to all other matters raised, I conclude that the appeal should be allowed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 334No official casework-database value to compare
    Extracted decision date · page 1
    11 September 2023Matches the official casework database
    Extracted site visit dates
    22 August 2023 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3323083
Application reference
00207/38/P2
Lead case reference
Not recorded
Planning authority
London Borough of Hounslow
Planning authority code
E09000018

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Allowed
Decision category
Allowed
Received date
26 May 2023
Valid date
26 May 2023
Start date
8 August 2023
Planning authority decision date
18 May 2023
Appeal decision date
11 September 2023

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
38435
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:27
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21