Appeal 3324709
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
11 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
the demolition of some outbuildings and removal of post and wire fence. Erection of a greenhouse, chicken coop and rain water storage unit and the remodelling of part of the garden.
Section 02
Decision
The appeal is allowed and planning permission is granted for the demolition of some outbuildings and removal of post and wire fence. Erection of a greenhouse, chicken coop and rain water storage unit and the remodelling of part of the garden at [site address] in accordance with the terms of the application, Ref 22/03570/FUL, subject to the conditions in the schedule below:
Section 03
Preliminary Matters
I have used the description of development in the Council’s decision notice and appellant’s appeal form as it more succinctly describes that for which permission is sought.
From my site visit it was evident that buildings of similar siting, scale and appearance to that for which permission is sought have been erected on site. The remodelling of the garden also appeared to have been largely completed. For the avoidance of doubt, the retrospective nature of the proposal does not have a bearing on my decision, which is made on the basis of the submitted drawings.
Section 04
[name]
The main issues are: a) whether the proposed development would be inappropriate development in the Green Belt having regard to the Framework and any relevant development plan policies; and b) the effect of the proposal on the openness of the Green Belt.
Section 05
Policy Context
The Framework states that other than in the case of specific exceptions, development in the Green Belt should be regarded as inappropriate. The proposal comprises both the remodelling of the garden and new outbuildings. Neither the Council nor the appellant clearly articulate under what part or parts of the Framework the proposal has been considered.
Paragraph 155(b) of the Framework allows for engineering operations in the Green Belt provided they preserve its openness and do not conflict with the purposes of including land within it. The Council considers the remodelling of the garden to be an engineering operation and does not raise an objection to this aspect of the scheme. Based on the information before me and my own observations on site, I have no reason to disagree with this conclusion.
With regard to the buildings, the appellant refers to them as being replacements, which I take to be a reference to the exception in Paragraph 154(d). It seems to me that provided the new buildings are in the same use and replace the previous curtilage buildings, they could reasonably be considered as replacement buildings under paragraph 154(d). The test of whether they would be “materially larger” would then need to be applied.
However, the appellant also makes reference to the buildings not being disproportionate. This appears to be a reference to the exception set out in Paragraph 154(c), which allows for the extension or alteration of a building. Provided that the new building would be in the same use, proposals to replace an existing curtilage building can be considered under paragraph 154(c). The test of whether it would be materially larger than the size of the original building would be applied.
The appellant also makes reference and appears to draw a comparison between the proposal and the provision of appropriate facilities on allotments, which are referenced in Paragraph 154(b) of the Framework. Whilst the gardens serving the appeal property are large, they are private and do not in my opinion correspond to or have the same character as allotments. Consequently, the proposal would not comply with the exception in Paragraph 154(b) of the Framework.
It does not appear to me that either of the main parties has sought to address the proposal on any of the other exceptions in the Framework.
Section 06
Assessment – [name]
The framework does not define materially larger and therefore it is a matter of planning judgement. However, the Courts have held that in considering whether a building is materially larger than what it will replace the exercise is primarily an objective one by reference to size. There is nothing in Paragraph 154(d) to indicate that a replacement building should be considered in relation to other surrounding development, as the exception only refers to whether it would be materially larger than the building it replaces.
The proposal would have a combined footprint of just over 70m2 more than what previously existed, which is over double the previous floorspace figure. I have not been provided with the comparative volumes but the new buildings would generally be wider, deeper and slightly higher. In the case of the greenhouse there would be a noticeably larger roof. As a result, it seems to me that the new buildings would be visibly larger in scale and bulk.
For these reasons, I find that collectively the new buildings would be materially larger than the buildings that existed and have since been replaced. Consequently, the proposal would not fall within this exception.
Section 07
Assessment - Extensions
Policy GB3 of the Allocations and Development Management Plan 2015 (ADMP) states that outbuildings within the curtilage of an existing dwelling in the Green Belt, will be treated as an extension under Policy GB1 if they are located within 5m of the existing dwelling. It appears to me that the outbuildings in this case would be over 5m from the dwelling and so the Council did not consider the proposal as an extension.
However, the 5m limitation set out in the ADMP is more restrictive than the Framework or case law. Consequently, I sought the views of the Council on the proposed buildings being considered as extensions under Paragraph 154(c). I have taken their views into consideration.
An outbuilding does not need to be physically linked to another building to be considered under Paragraph 154(c). It is reasonable to take into account whether the proposal would be a ‘normal domestic adjunct’. For this, consideration could be given to the purpose and use of the proposed building, its relationship with the original building and its size.
It seems to me that the previous garden buildings could reasonably be considered to have been normal domestic adjuncts to the dwelling. Likewise, the proposed outbuildings would be used for purposes clearly related to the occupation of the dwelling. They would be in the same broad location on the site, relatively close to the dwelling and within a group of buildings closely associated with it. Therefore, I am satisfied that the proposed outbuildings can be considered as extensions to the dwelling.
I also noted some other structures on the wider property, but from what I saw these are for occasional use with the garden. Given their nature, distance, and relationship to the dwelling, they did not appear to be normal domestic adjuncts, to be considered as extensions to, or read as, part of the dwelling.
Having regard to the planning history of the site, it is apparent that the floorspace of the dwellinghouse itself has previously been extended by some 50%. Policy GB1 of the ADMP seeks to limit increases through extensions to no more than 50% above the floorspace of the "original" dwelling. The proposal before me adds approximately 70m2 of floorspace, and I am aware that there are other, existing outbuildings such as the shed and garage which are to be retained and may not have previously been considered as ‘extensions’.
The Framework does not define ‘disproportionate’ and it is therefore a matter of planning judgement. Furthermore, ‘size’, which is the test in the Framework, encompasses more than simply a comparison of floorspace figures. It can reasonably be taken to include such factors as volume, height, external dimensions, visual perception etc. As the Framework is more up to date than the ADMP, its approach is to be preferred when assessing the issue further.
The proposal results in larger outbuildings than those that previously existed. The additional scale and height find particular expression in the greenhouse, although it is positioned and of a scale that remains subservient to the dwelling. Indeed, the heights of the buildings generally decrease the further away they are from the dwelling and in line with the fall of the land. Overall, these additions would not be considered dominant in their size and massing and integrate with the dwelling and site as a whole.
The existing extensions do not appear to harm the proportions or dominate the original building. However, I recognise that small additions, which on their own may not be disproportionate, can incrementally result in disproportionate additions over and above the size of the original building.
Therefore, as a matter of judgement, I find the scale of the proposed alterations, together with the previous extensions, whilst appearing larger than what previously existed, would not quite tip over into being disproportionate to the size of the original building. Therefore, in this instance these works would not be inappropriate development within the Green Belt.
Section 08
Conclusion
For the reasons set out above, I find that the proposal would not amount to inappropriate development in the Green Belt. Accordingly, it does not conflict with Paragraphs 154(c) and 155(b) of the Framework, the relevant provisions of which I have set out above.
Section 09
Openness
Given that the proposal would not constitute inappropriate development in the Green Belt, the Framework does not direct me to assess the impact of the proposal on the openness of the Green Belt. However, Policy GB3 of the ADMP states permission will be granted for outbuildings located over 5 metres from the existing dwelling where they are ancillary to the main dwelling in terms of function and design and not materially harmful to the openness of the Green Belt through excessive bulk or visual intrusion. The Council acknowledges that there would be no adverse impact on openness from the ground works and I have no reason to disagree with this conclusion.
The proposed greenhouse would be a pitched roof and glazed with a brick plinth; however, its size would be commensurate with that of the appeal site and dwelling, which are both considerable. The chicken coop is a much smaller building which has a flat roof and two sides of open mesh.
They would be ancillary to the main dwelling, and I am satisfied that their designs reflect their uses when seen as part of the wider appeal site in association with the dwelling. Their siting would not prevent them from functioning and appearing as ancillary to the dwelling.
The base of the greenhouse is set down below ground level and is positioned between two retained outbuildings and adjacent to the existing boundary and mature planting. The chicken coop would be positioned discreetly in the corner of the garden. They would be broadly positioned where previous outbuildings stood. The water storage containers and koi pond are relatively small, discreet structures that do not sit prominently above ground level. The water storage containers are positioned to the rear of the other outbuildings.
The wording of Policy GB3 implicitly acknowledges that change can occur without the openness of the Green Belt being materially harmed. Given the buildings and their wider context, I am satisfied that they would not be visually intrusive or represent excessive bulk that would materially harm the openness of the Green Belt.
The Council’s Supplementary Planning Document: Development in the Green Belt 2015 (SPD) provides guidance that new outbuildings over 5m from a dwelling should not exceed 40m2. However, in this instance, there were already buildings over this suggested limit and whilst it provides a useful rule of thumb, the SPD is guidance and not policy. Indeed, having considered the proposal on its own merits I have already concluded that the proposal would satisfy the broader objectives of Policy GB3.
Section 10
Conditions
As the works appear to have been implemented, it is not necessary for me to impose the standard time limit. However, in the interests of certainty a condition that lists the approved plans is necessary.
The greenhouse is the principal and most prominent of the buildings within the scheme. However, as the external materials to be used for it are specified on the approved drawings a further condition setting this out is unnecessary.
It appears that some ecological losses may have occurred as part of the works associated with the development. It is therefore reasonable and necessary for a scheme of ecological enhancement to be implemented alongside the development.
Section 11
Conclusion
For the reasons set out above and having regard to the Framework and the development plan as a whole as well as all other matters raised, I conclude that the appeal should succeed.
The development hereby permitted shall be carried out in accordance with the approved plans listed below: Site Location Plan Site Plan as Proposed - WF-A–101 Rev P04 [name] as Existing (Demolished) - WF-A–201 Rev P03 [name] as Proposed - WF-A–202 Rev P03 [name] & [name] & [name] as Existing (Demolished) - WF-A– 203 Rev P02 Shed (7 sq m) Elevations as Existing (Demolished) - WF-A–204 Rev P02 [name] and Sections - WF-A– 205 Rev P01 [name] as Proposed - WF-A– 206 Rev P01 [name] as Existing (Maintained) - WF-A– 207 Rev P02 [name] (next to Garage) Elevations as Existing (Maintained) - [name]–208 Rev P02 [name] as Existing (Maintained) - WF-A-209 Rev P02 [name] & DD as Existing (Demolished) - WF-A–301 Rev P02 [name] & [name] and Overlay - WF-A–302 Rev P02 [name] & BB as Existing - WF-A–303 Rev P01 [name] & BB as Proposed - WF-A–304 Rev P01 [name] & [name] & [name] - WF-A–305 Rev P01 Fish/Koi Pond Proposed Section - WF-A–306 Rev P01 [name] – 22/2729 (Drawing 01) [name] & B - 22/2729 (Drawing 03) [name] & D – 22/2729 (Drawing 04)
Within 3 months of the date of this decision, an ecological enhancement scheme (including timetable for implementation) shall be submitted in writing to the local planning authority for approval. The development shall be carried out in accordance with the approved details which shall be retained thereafter. END
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 272No official casework-database value to compare
- Extracted decision date · page 1
- 18 March 2024Matches the official casework database
- Extracted site visit dates
- 7 February 2024 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3324709
- Application reference
- 22/03570/FUL
- Lead case reference
- Not recorded
- Planning authority
- Sevenoaks District Council
- Planning authority code
- E07000111
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- 96 m²
- Number of residences
- 0
- Site in Green Belt
- Yes
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Allowed
- Decision category
- Allowed
- Received date
- 23 June 2023
- Valid date
- 23 June 2023
- Start date
- 11 October 2023
- Planning authority decision date
- 26 May 2023
- Appeal decision date
- 18 March 2024
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 48338
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:27
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21