Appeal 3328011

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

10 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

the erection of a single-storey rear extension which will extend 3500mm from the rear facade of the existing building and will be 7270mm wide.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Preliminary Matters

    I have taken the description of development from the Council’s decision notice and appellant’s appeal form as they more succinctly describe that for which permission is sought.

    A revised National Planning Policy Framework (the Framework) was published by the Government after the determination of the planning application. It does not raise any new considerations in relation to this appeal.

  3. Section 04

    [name]

    The main issues are: a) whether the proposed development would be inappropriate development in the Green Belt having regard to the Framework and any relevant development plan policies; b) the effect of the proposal on the openness of the Green Belt; and c) whether any harm by reason of inappropriateness, and any other harm, would be clearly outweighed by other considerations, so as to amount to the very special circumstances required to justify the proposal.

  4. Section 05

    Whether Inappropriate Development

    The Framework establishes that building in the Green Belt would be inappropriate unless it would meet one of the listed exceptions. Paragraph 154(c) explains that the extension or alteration of a building would not be inappropriate development provided that it would not result in disproportionate additions over and above the size of the original building. Policies DP10 and DP13 of the Tandridge Local Plan 2014 (TLP) are broadly consistent with the Framework insofar as seeking to ensure inappropriate development in the Green Belt is resisted and that extensions or alterations to buildings in the Green Belt are not disproportionate to the original building.

    The Framework explains in its glossary that the original building is the building that existed on 1 July 1948 or, if constructed after this time, as it was built originally. For the purposes of this appeal, the TLP defines the ‘original building’ as it existed on 31 December 1968 or, if constructed after 1968, as it was built originally.

    Moreover, Policy DP13 also notes that when assessing proposals for the extension of a building which is itself a replacement of a previous building (as is the case here), the Council will consider that previous building in comparison with the replacement building and the proposed extension, in order to determine whether the proposal would result in a disproportionate addition.

    The Council has assessed the proposal as per Policy DP13. The Appellant asserts that in relation to this appeal, it is the replacement building that should constitute the ‘original building’ and be the baseline for assessing whether the proposal would be disproportionate.

    The judgement in Guildford Borough Council v SSLUHC & [name], [2023] EWHC 575 (Admin) has established that in a planning policy context such as the one before me, it is the earlier, previous building which should be the baseline for any consideration as to the proportionality of further development, rather than the replacement building. This is a material consideration of substantial weight in my consideration of this appeal.

    There is a further dispute between the main parties as to the exact sizes of the pre-existing and replacement buildings. Nevertheless, if I take the figures presented by the appellant, and based on the March 2012 appeal decision, the pre-existing building was said to be 518m3. It is not clear from the evidence presented whether this figure included the double garage and conservatory that were approved in 1994 and 2002 respectively but it seems likely that they would have been included within this 518m3 figure. If that were the case the original building may well have been smaller than 518m3.

    However, putting that to one side for the moment, the appellant confirms that the existing property was constructed to a volume of 863m3. A first floor extension and new bay windows have subsequently extended the building by a further 46m3. This would give the current building a volume of 909m3. This is approximately 75% over the volume of the stated pre-existing figure of 518m3.

    The appellant also provides a comparison of footprints. However, the reference to pre-existing footprint refers to ‘buildings’ and so presumably includes the double garage approved in 1994. The difference between the footprint of the original building and what would result from the current proposal is therefore likely to be greater than the appellant suggests.

    The proposed extension would have a volume of around 74m3. This represents an overall volumetric increase to the existing dwelling of around 14%, when taken together with the previous extensions and alterations to this building. This would be a modest and limited extension in comparison to the existing building. Nonetheless, it would further increase the mass of development on site when compared to the baseline as set by the size of the pre-existing building.

    Based on the evidence before me, there would be a substantial increase in the size of the dwelling when compared to the more modest original building. Therefore, as a matter of judgement, I conclude that the overall size of the building as now proposed cannot reasonably be considered to result in anything but disproportionate additions over and above the size of the original building.

    Thus, having regard to the Framework and Council policies DP10 and DP13 as outlined above, I am unable to conclude other than that the extension would be inappropriate development in the Green Belt.

  5. Section 06

    Openness

    Paragraph 142 of the Framework states: ‘the fundamental aim of Green Belt policy is to prevent urban sprawl by keeping land permanently open; the essential characteristics of Green Belts are their openness and their permanence’. Openness is not defined in the Framework but in determining the nature and extent of any impact on Green Belt openness it is necessary to assess both spatial and visual impacts.

    The proposed extension would be to the rear of the property, positioned between the two existing bay windows on this rear elevation. It would be a largely glazed structure and have the existing dwelling as an immediate backdrop.

    Maintaining openness does not necessarily mean that there can be no change, as the overall situation needs to be considered in relation to both the visual and spatial effects of the proposed development. Notwithstanding that there may have been a reduction in openness across the site in the past, having regard to just the current proposal, I do not find harm to Green Belt openness.

  6. Section 07

    [name]

    The current dwelling is said to be in an entirely different location to the pre-existing dwelling and thus there was previously no dwelling on this part of the site. Whilst the replacement dwelling may have been set back a couple of metres from where the previous building stood, it was nevertheless a direct replacement for an existing building. This is evident from the description of development ‘Demolition of dwelling. Erection of dwelling’ in the TA/2011/1222 decision notice. This is further confirmed by condition 6 of the permission, which clearly required the demolition of the existing dwelling and outbuilding within 3 months of the replacement dwelling being occupied. From what I have read, this positioning seems to have been in order to minimise the effect of the building on the wider area and there is nothing before me to suggest that this means it should not be regarded as a replacement.

    The appellant notes that had permitted development rights not been removed from the existing dwelling by condition then the proposal could be erected without needing the current application and appeal. However, this is not an appeal against that condition or its reasons for being imposed.

    I am also mindful that the decision to permit the replacement dwelling was taken in a different policy context and pre-dates the current TLP and more specifically Policy DP13. The current policy context carries far greater weight than the Green Belt not being part of the rationale for previously withdrawing permitted development rights.

    The appellant draws my attention to how the Council assessed some previous proposals on the site. Their approach in these schemes, as well as the current case, is said to be flawed. However, I have considered the current proposal on the basis of the evidence before me, including the Framework, development plan policies and case law. Accordingly, the appellant’s concerns regarding the Council’s approach to decision making does not alter my own conclusions.

  7. Section 08

    Green Belt Balance

    The development is inappropriate development in the Green Belt which by definition is harmful, notwithstanding there is no harm arising from the extension to openness or the purposes of including land within the Green Belt. As such, the Framework requires that the harm by reason of inappropriateness be given substantial weight and that inappropriate development should not be approved except in very special circumstances. Very special circumstances will not exist unless the harm to the Green Belt and any other harm is clearly outweighed by other considerations.

    The weight I could ascribe to those considerations in favour of the proposed development would be limited and insufficient to justify the proposed development, owing to the substantial weight that should be attached to any harm to the Green Belt. Very special circumstances do not therefore exist.

  8. Section 09

    Planning Balance

    There would be an overall conflict with policies in the TLP when taken as a whole and the proposal would be contrary to the provisions of the Framework in relation to the protection of the Green Belt. Collectively, these weigh heavily against the proposal and there are no other considerations which outweigh them.

    Therefore, having regard to the development plan and all other material considerations, including the Framework, the appeal should not succeed.

  9. Section 10

    Conclusion

    For the reasons given above, I conclude that the appeal should be dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 272No official casework-database value to compare
    Extracted decision date · page 1
    18 March 2024Matches the official casework database
    Extracted site visit dates
    7 February 2024 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3328011
Application reference
TA/2022/1434
Lead case reference
Not recorded
Planning authority
Tandridge District Council
Planning authority code
E07000215

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Unknown
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
23 m²
Number of residences
0
Site in Green Belt
Yes
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
17 August 2023
Valid date
23 August 2023
Start date
31 October 2023
Planning authority decision date
7 June 2023
Appeal decision date
18 March 2024

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
48363
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:27
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21