Appeal 3331014
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
6 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
described as air source heat pump being installed.
Section 02
Decision
The appeal is dismissed.
Section 03
Preliminary matter
Since the appeal application was refused the National Planning Policy Framework 2021 has been replaced. Within the current National Planning Policy Framework December 2023 (Framework) paragraphs 126, 127, 128, 129, 130 and 134 of the Framework 2021 have been renumbered 131, 132, 133, 134 & 139, although their content is unchanged. Paragraphs 7–13 remain unaltered and paragraph 14 is not material to the appeal proposal. For the avoidance of any doubt, I confirm that in this decision I have referred to the December 2023 Framework.
For the avoidance of any doubt, I confirm that this decision purely addresses the location of the proposed air source heat pump at the front of the dwelling. It does not address the previously proposed location at the side of the dwelling.
In their appeal statement the appellant states that they have offered to erect a seven foot fence along the boundary with [address] (No.31). However, this did not form part of the appeal application and due to its height it would need to be made the subject of a separate planning application. As such it falls outside the scope of this decision.
Section 04
Main Issue
The main issue is the effect of the proposal on the living conditions of the occupiers of No.31, with particular regard to noise and disturbance.
Section 05
Reasons
[address] is a quiet residential road that is characterised by detached and semi-detached bungalows and chalet bungalows that are set back from [address] behind good sized front gardens. The appeal site is located within a row of bungalows/chalet bungalows with uniform front building lines and which project close to their side boundaries.
As stated in paragraphs 157, 162, 163 & 164 of the Framework the planning system supports the transition to a low carbon future and that significant weight should be given to the need to support energy efficiency and low carbon heating improvements to existing buildings. This includes through the installation of heat pumps. Policies SPO9 and WCS14 of the Wealden District Core Strategy Local Plan 2013 (CS), policy EN1 of the Wealden Local Plan 1998 (LP) and the Sustainability section of the [name] 2008 (WDG), are consistent with this.
Sustainable development also takes into account other factors and in relation to the appeal proposal, [name] SPO13, [name] EN1, EN27 & HG10, Section 2 and paragraphs 131 & 135 of the Framework, collectively seek to provide satisfactory living conditions. The living conditions of existing residents should be protected from unacceptable harm due to a range of factors including noise.
Whilst the council’s decision notice also refers to paragraphs 132, 133, 134 & 139 of the Framework, in relation to the appeal proposal I do not find them to be of specific relevance to the council’s reason for refusal.
Regarding background noise levels the current MCS 020 Permitted Development Planning Standard for air source heat pumps, when measured from the nearest neighbouring property is assumed to be 40 dB(A) Lp. The submitted specifications for the proposed air source heat pump states that its sound level would be 62dBA.
The proposed air source heat pump would be sited less than five metres from the side wall at No.31, which contains windows. It would also be located within the recessed part of the front elevation where it would be contained within an open fronted porch area. Whilst this porch enclosure and the boundary fence between the appeal property and No.31 would likely help contain some noise generated by the air source heat pump the adjacent windows and door within the recessed area at the front of the appeal dwelling could reflect noise towards No.31.
Having regard to these factors the Council’s environmental health officer has calculated that the noise generated by the proposed air source heat pump could be between 4dB and 8dB higher than the 42dB specified in the MCS 020. I appreciate that this calculation is based on assumptions because the precise location of the closest windows at No.31 are not provided and the actual potential noise attenuation that would be derived from the enclosed location of the air source heat pump is unknown. Notwithstanding this, it indicates that the noise generated by the proposed air source heat pump would have the potential to unacceptably harm the living conditions of the occupiers of No.31.
To demonstrate otherwise would require a more comprehensive noise assessment, such as that based on the methodology of BS 4142:2014+A1:2019, referred to in the Review of Air Source Heat Pump Noise
Section 06
Emissions, Permitted Development Guidance and Regulations Final Report
In reaching this conclusion I have taken into account the low background noise levels within this part of [address].
It is acknowledged that the air source heat pump would not be used during the summer months. However, this would not negate the harm caused when it would be operated.
For these reasons I find that the potential harm to the occupiers of No.31 would clearly outweigh the personal benefits identified by the appellant and the positive contribution the proposal would make in supporting energy efficiency. It is also not a matter that could be satisfactorily addressed through the imposition of conditions.
I conclude that, in the absence of a specific noise assessment, the appellant has failed to demonstrate that the noise generated by the proposed air source heat pump would not have an unacceptable harmful impact on the living conditions of the occupiers of No.31. Accordingly, it would conflict with [name] EN1, EN27 & HG10, [name] SPO9, SPO13 & WCS14 and Section 2 and paragraphs 131 & 135 of the Framework.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 1220No official casework-database value to compare
- Extracted decision date · page 1
- 7 February 2024Matches the official casework database
- Extracted site visit dates
- 24 January 2024 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3331014
- Application reference
- WD/2023/1438/F
- Lead case reference
- Not recorded
- Planning authority
- Wealden District Council
- Planning authority code
- E07000065
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 10 October 2023
- Valid date
- 10 October 2023
- Start date
- 22 November 2023
- Planning authority decision date
- 8 September 2023
- Appeal decision date
- 7 February 2024
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 46165
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:27
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21