Appeal 3337501
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
7 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
enlargement/extension of hipped roof including side dormers.
Section 02
Decision
The appeal is dismissed.
Section 03
Preliminary Matters
I have adopted the description of development as set out in the decision notice as this is more concise than that on the application form.
Since the application was refused planning permission, a revised version of the
Section 04
National Planning Policy Framework (Framework) was issued in December
However, the relevant design policies of the Framework remain largely the same as those in the previous version, albeit some of the paragraph numbering has changed.
The Appellant has raised an issue in relation to the lawfulness of certain elements of the proposed development. Within the context of an appeal that simply seeks planning permission and is submitted under section 78 of the Town and Country Planning Act 1990 (T&CPA), whether a development or part of it is permitted development and lawful is not a matter that I can address. It remains open to the Appellant to submit an application for a Lawful Development Certificate for proposed development under section 192 of the T&CPA if they consider that any part of the development is lawful, and the determination of that application would not be affected by my decision on this appeal.
A previous proposal for a roof extension to the host property was dismissed on appeal on 2 December 2019 (ref. APP/V1260/D/19/3233468) (2019 Appeal). I have had regard to that decision, as well as the subsequent applications to extend the roof to the host property, in determining this appeal.
Section 05
Main Issue
The main issue is the effect of the proposed development on the character and appearance of the host property and surrounding area.
Section 06
Reasons
The appeal site comprises a large detached two storey property in a Georgian style located on the northern side of [address]. The host property appears to retain a number of its original features including a parapet wall at roof level behind which is a modest shallow pitched hipped roof. As with other properties on this side of the road, the host is prominent in views from public vantage points and in particular when approaching the site from either direction. Even though the pitched hipped roof is low key and set behind the parapet, as I observed on site, it is still visible in views from the road. As such, the host property has a cohesive and pleasing appearance and makes a positive contribution to the streetscene.
The north side of the road comprises similar detached two storey properties, some with accommodation in the roof. A number of these properties have been altered, extended or remodelled, particularly at roof level. In most cases these works have been undertaken sympathetically, are not visually dominant and integrate well with the design and appearance of the property in question. Even so, there is no uniform character with a variety of styles, built forms (including roofs), heights and materials. On the southern side of the road, the scale of development is more modest with a mixture of bungalows, chalet bungalows and some two storey properties.
The appeal proposal involves increasing the mass and volume of the existing pitched hipped roof. The proposed roof pitch would be steeper, it would extend closer to the front elevation and include two new large side dormers. The main ridge to the existing roof would be elongated and include a large expanse of flat roof.
Within the above context, I consider that the bulk, proportions, width and design of the enlarged and extended roof would be excessive and would result in an inappropriate addition to the host property. The proposal would not be sympathetic to the original design or character of the host. It would replace the existing well defined and low key hipped roof, with an incongruous and prominent addition that would be less subservient than the existing roof and out of keeping with the proportions of the host property. The excessive bulk and mass of the new roof would be accentuated by the proposed side dormers, both of which would have a significant height, depth and width. Both dormers would also include blank elevations, resulting in a poor and unsympathetic design feature.
The proposal would not represent a high quality design and would not integrate well or respect the character of the host. It would visually dominate the hosts appearance when viewed from the road. [name] note the approach of seeking to reflect the roof pitch/form as on [address] (No.85), to the east of the appeal site, this is not the correct design approach to adopt in this instance in that the proposal results in an awkward juxtaposition with the original front elevation of the host. It would disrupt the rhythm of the existing modest roofscape and result in the loss of an integral roof feature.
Overall, the proposal would not sit comfortably on the host property leading to significant harm to the character and appearance of the host and surrounding area. The Appellant contends that the proposal would largely be screened from the road behind the retained parapet wall. I do not agree. [name] indicated earlier, the existing hipped roof is already visible from the road and the increased bulk, proportions and unsympathetic design of the proposal would be even more visible and thus highly prominent within the streetscene.
Turning to the 2019 Appeal, that proposal involved a mansard roof extension which, by virtue of its excessive scale, increase in volume, elongated ridgeline and noticeable expanse of flat roof, the Inspector found to be visually dominant and a top heavy addition to the host. [name] accept that the current proposal involves a different style of extension, the changes, compared to the 2019 Appeal scheme, are modest. [name] have explained above, even with these changes the appeal proposal remains unacceptable. In this respect the findings of the previous Inspector have not been addressed. The fact that No.85 has been extended and altered since the 2019 Appeal decision does not, for the reasons outlined above, affect my findings on this issue, bearing in mind also the requirement to assess each case on its individual merits.
As such, the proposal would conflict with policy CS41 of the Bournemouth Local Plan: [name] (October 2021) (BLP) where it requires development to secure a high quality of design and to respect or enhance local distinctiveness as well as the character and appearance of the site and its surrounds. That approach remains broadly consistent with paragraphs 135 and 139 of the Framework. The proposal would also conflict with various principles in the Residential extensions: A Design Guide for Householders (September 2008) ([name]) including: part 2.1 which requires extensions to respect the character of the house and not to dominate it; Part 2.2 which requires extensions to maintain or enhance the character of the house and be subservient to it; and, part 3.3 which requires roof alterations specifically dormers to be set well below the ridge line, well above the eaves and in from the sides, to avoid flat roofs and horizontal emphasis and to also avoid an unbalancing effect on the existing property through too many dormers.
The Design Guide also remains broadly consistent with the Framework. [name] accept that paragraph 135 of the Framework also states that being sympathetic to local character should not prevent or discourage appropriate innovation or change, the appeal proposal results in a development that would be harmful to the character and appearance of the host and surrounding area. Although this assessment involves an element of judgement, there is, unfortunately, nothing innovative in the design of the proposal or any other considerations that would lead me to reach a different finding.
Accordingly, I find that the proposal would fail to comply with policy CS41 of the BLP, the [name] and the corresponding policies of the Framework.
Section 07
Conclusion
For the reasons given above and having taken all the matters raised into account, I conclude that the appeal should be dismissed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 248No official casework-database value to compare
- Extracted decision date · page 1
- 12 April 2024Matches the official casework database
- Extracted site visit dates
- 3 April 2024 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3337501
- Application reference
- 7-2023-20649-H
- Lead case reference
- Not recorded
- Planning authority
- Bournemouth, Christchurch and Poole
- Planning authority code
- E06000058
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Unknown
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 24 January 2024
- Valid date
- 24 January 2024
- Start date
- 15 February 2024
- Planning authority decision date
- 1 November 2023
- Appeal decision date
- 12 April 2024
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 49488
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:27
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:24
- Record updated
- 24 August 2026 at 16:21