Skip to main content
Official casework recordDismissedCurrent release

Appeal 3340199

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

6 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

a single storey rear extension.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Preliminary Matters

    Under Article 3 (1) and Schedule 2 Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) (the GPDO), planning permission is granted for the enlargement of a dwellinghouse subject to limitations and conditions.

  3. Section 04

    [name]

    The main issue is whether the proposal would be permitted development.

  4. Section 05

    Reasons

    There is no dispute that the development would have a width greater than half the width of the original dwellinghouse. The main issue of contention is whether the proposal would extend beyond a wall forming a side elevation of the original dwellinghouse contrary to the limitation within A.1 (j)(iii) of the GPDO.

    The appeal property has been previously extended at ground floor across the full width of the property. I have no substantive evidence before me to indicate the appearance of the rear elevation of the property prior to the extension being constructed. However, existing drawings do indicate the original rear building line was staggered at ground floor. The appellant has identified that the approximate depth of this feature is between 0.25m to 0.3m. Although it is recessed and covered by the first floor, the plans show a clear projection, and stepped rear original building line. I do not disagree that this is an architectural feature, and not a structural part of the dwelling, but this does not preclude it from also being side wall.

    The appellant has supplied numerous appeal decisions of varying ages on this matter. In the [address] appeal1 the Inspector considered ‘the nature, location and projection of a wall of similar depth did not constitute a wall forming a side elevation of the original dwelling. Like this appeal, this was not in situ although the submitted plans are not comprehensive. However, the Inspector was able to visit that property and referred to specific features, which are not evident from the information provided to me. I am therefore of the view that they had evidence or the benefit of first hand observation, which is not before me, to inform their view as a matter of fact and degree.

    The wall in the [address] appeal2 was also a very short section of wall that served only to link the different parts of the ground floor rear elevation and the Inspector also found as a matter of fact and degree that it formed part of the rear wall of the original dwelling. With the [address] appeal3 it is clear that the rear façade was in alignment at ground floor level across the rear of the property. The contested feature was set at height above this. In the Endellion appeal4 the wall in question was described as a shallow, two storey projection which was evidently intended to provide some articulation to the rear elevation.

    With the dismissed [name] appeal5 the appellant has suggested that the whole geometry of the external envelope of the building and total scale and visibility of the of the upper storey needs to be considered, thus drawing a variance with this decision. However, that Inspector determined that appeal based on the lawfulness of the proposed development as required. The planning merits and matters such as design, scale and visibility are not referred to within the limitations of the GPDO. [name] was to take this argument, all the above appeal properties appeared to be substantial dwellings. In the context of the scale of those dwellings, the side-walls referred to would be very minor features.

    As such there are numerous appeals which support and conflict with the appellant’s case, and I have carefully considered these. Some of them pre-date the current Permitted Development Rights for Householders - Technical Guidance (2019). However, as is explained in this document a wall forming a side elevation of a house is any wall which cannot be identified as a front wall or rear wall. This point is illustrated by a diagram in the Guidance showing a house with stepped rear projections, the side walls of which are labelled as walls forming a side elevation.

    Although no longer in situ, and the projection was quite small, I am of the view that there was a short piece of wall which was not rear-facing. It is not a front wall and it is side-facing; so it has to be treated as a side elevation. The proposed extension would project beyond this side elevation and would have a width greater than half the width of the original house. All the facts in those appeals are very different from the situation in this appeal where I have found that the 0.3m is part of the ground floor element of a wall forming a side elevation of the dwellinghouse and ultimately, I have insufficient evidence of this wall to conclude otherwise. 1 Appeal ref: APP/B1930/X/10/2133372 2 Appeal Ref: APP/L5810/X/18/2180519 3 Appeal Ref: APP/L5810/X/18/3198886 4 Appeal Ref: APP/Y3615/X/16/3142651 5 Appeal Ref: APP/M3645/X/16/3154333

    I do not see good reason to interpret the GPDO other than in accordance with the Guidance. In my opinion there is no base-line for side-wall depth and the GPDO and guidance as drafted does not provide for flexibility, it simply refers to a wall forming a side elevation.

    Therefore, the proposed extension would extend beyond a side elevation of original house and would be more than half the width of the original dwellinghouse. The appeal scheme would, therefore, not comply with the limitations contained within paragraph A.1 (j)(iii) of the GPDO.

    [name].3 (a) of the GPDO requires the materials used in any exterior are of a similar appearance to those used in the construction of the exterior of the existing dwellinghouse. The host dwelling has a rendered ground floor appearance, and tile hanging on the upper floor. I find that the proposed render would be of a similar appearance to that used in the construction of the exterior of the existing dwellinghouse on its current extension. The proposal would therefore satisfy the relevant provision A.1(g) of the GPDO.

    There is also a dispute over the depth of the extension. I consider that this falls within the remit of A.4 (3)(b) of the GPDO that the developer has provided insufficient information to enable the authority to establish whether the proposed development complies with the limitations and conditions. Although the application form states that the depth of the development would be 6m, the proposed plans clearly show a depth of 5700mm from the original wall aligned with the first floor. However, as the recessed original rear elevation is set in around 0.3m the extension should not exceed 6m from this point. I therefore have no substantive evidence that the proposal exceeds the limitations and would comply with the provisions of A.4 (3)(b) of the GPDO.

    The proposal would comply with the provisions of A.3 (a) and A.4 (3)(b) of the GPDO. However, I conclude that the extension would not accord with limitations of A.4 (J)(iii) of Part 1, Class A, Schedule 2 of the GPDO. Therefore, the development does not constitute permitted development.

  5. Section 06

    Conclusion

    For the reasons given above, I conclude that the appeal is dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted decision date · page 1
    11 December 2024Matches the official casework database
    Extracted site visit dates
    18 November 2024 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3340199
Application reference
23/03133/PAEXT
Lead case reference
Not recorded
Planning authority
Royal Borough of Kingston Upon Thames
Planning authority code
E09000021

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
3. Refused prior approval of permitted development rights
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
No
Historic building grant made
No
Relates to a conservation area
No
Flooding is an issue
No
Site within an AONB
No
Site within an SSSI
No

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
7 March 2024
Valid date
18 March 2024
Start date
7 May 2024
Planning authority decision date
18 December 2023
Appeal decision date
11 December 2024

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
61612
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:28
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21