Skip to main content
Official casework recordAllowedCurrent release

Appeal 3340953

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

7 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

side dormer roof extension.

  1. Section 02

    Decision

    The appeal is allowed and planning permission is granted for a side roof extension at [site address] in accordance with the terms of the application, Ref 23/2889/HOT, dated 25 October 2023, subject to the following conditions:

    The development must be carried out in accordance with the provisions of the Planning Fire Safety Strategy, prepared by Raw Architects Ltd, dated 02/2023, received 25th October 2023, and retained as such thereafter.

    The development hereby permitted shall be carried out in accordance with the following approved plans: 2051 P101; 2051 P102; 2051 P103; and 2051 P110.

  2. Section 03

    Preliminary Matters

    On my site visit I observed that the development has been completed, along with a hip to gable extension and a rear dormer. According to the information before me, the Council issued a Lawful Development Certificate in April 2023 under ref. 23/0246/PS192 for a hip to gable extension and rear dormer at the property. The appeal is therefore in relation to obtaining retrospective permission for the side dormer roof extension.

    The Council has referred to discrepancies in the drawings. Any discrepancies in relation to other parts of the dwelling such as the number of roof lights in the single storey side extension are not material to the appeal proposal. I can also see no significant discrepancies between the drawings in relation to the proposed side dormer roof extension. I shall therefore determine the appeal on the basis of the drawings submitted to and determined by the Council.

  3. Section 04

    Main Issue

    The main issue is the effect of the side dormer extension on the character and appearance of the host dwelling, the semi-detached pair and the surrounding area.

  4. Section 05

    Reasons

    The appeal concerns a two-storey, semi-detached dwelling which is paired with [address]. It is located in a row of semi-detached dwellings of a similar original design although several have been subsequently altered and extended.

    The appeal is for a side dormer roof extension. It is positioned on the side elevation of a hipped roof forward projection which is a defining feature of the appeal property and the other dwellings in the same row.

    The Council’s Supplementary Planning Document – [name] and [name] (2015) whilst non-statutory, provides useful guidance. It states that roof extensions should be ‘in-scale’ with the existing structure and should not project above the ridgeline. Roof extensions should not dominate the original roof and should keep existing profiles.

    The side dormer that has been constructed at No 49 is set slightly down from the both the main ridge of the dwelling and the ridge of the hipped roof forward projection on which it sits. It is also set in from the side elevation of the newly constructed gable roof and has been constructed in matching materials. The dormer extension is set back from the front elevation of the dwelling which enables the original roof profile to be appreciated. In my opinion, the dormer is not an unduly prominent feature of the roof of the dwelling and is ‘in-scale’ with the existing structure. As such I find that it does not detract significantly from the original character and appearance of the dwelling and is a form of development that complies with most of the aims and objectives of the SPD guidance.

    The hip to gable extension which has been constructed at the appeal property would on its own, cause an imbalance between the pair of semi-detached properties. Whilst the dormer adds to the unbalanced appearance, it is not a highly prominent feature and, in my view, does not result in any significant adverse effects on the character and appearance of the semi-detached pair, or the surrounding area. Furthermore, the appellant refers to a planning application for a side dormer in respect of the adjoining semi, [address], and although I do not have confirmation of the outcome of this application, there is a reasonable likelihood that in the future a similar form of development may be sought at that property.

    I also note the dormer extensions on the adjacent pair of semi-detached houses, Nos 43 and [address]. I acknowledge the Council’s comments that the roof extensions at Nos 43 and 45 were the subject of Lawful Development Certificates rather than applications for planning permission granted by the Council. The Council also state that the decision in respect of the side dormer extension at No 45 appears to have been issued in error and that the extensions at Nos 43 and 45 have not been carried out in accordance with the drawings submitted with the relevant applications and are subject to enforcement investigations.

    Notwithstanding the Council’s comments and having regard to the information provided by the appellant, it seems that at both 43 and [address] a form of dormer extension on the front/side roof slope has been confirmed as being lawful by the Council. There are also other examples of dormer roof extensions near to the appeal site which are also visible from [address] and according to my observations, such extensions form part of the established character of the area whether or not they benefit from planning permission or have been constructed under permitted development rights. I therefore conclude that the side dormer extension has not resulted in any significant harm to the character and appearance of the surrounding area.

    My overall conclusion is that the side dormer extension does not have a harmful effect on the character and appearance of the host dwelling, the semi-detached pair or the surrounding area. Thus, I find that it complies with Policy D4 of the London Plan 2021 and Policy LP1 of the London Borough of [site address] Local Plan (2018) which together require development to be of a high architectural and urban design quality which respects, contributes to and enhances the local environmental character.

  5. Section 06

    Conditions

    As the proposed development is retrospective, it is not necessary to impose the standard implementation or matching materials conditions. I have however imposed the approved plans condition for clarity and a fire strategy condition in the interests of the safety of the occupiers of the dwelling. I am not convinced of the need for a condition requiring a Flood Risk Assessment or [name] given evidence before me and the small-scale nature of the appeal proposal.

  6. Section 07

    Conclusion

    For the reasons given above, I conclude that the appeal should be allowed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 334No official casework-database value to compare
    Extracted decision date · page 1
    12 June 2024Matches the official casework database
    Extracted site visit dates
    21 May 2024 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3340953
Application reference
23/2889/HOT
Lead case reference
Not recorded
Planning authority
Richmond Upon Thames London Borough Council
Planning authority code
E09000027

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Unknown
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Allowed
Decision category
Allowed
Received date
19 March 2024
Valid date
23 March 2024
Start date
30 April 2024
Planning authority decision date
4 January 2024
Appeal decision date
12 June 2024

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
52362
First seen
20 August 2026 at 14:24
Last seen
20 August 2026 at 16:27
Removed from release
Not recorded
Record created
20 August 2026 at 14:24
Record updated
24 August 2026 at 16:21