Appeal 3346895
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
6 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
described as “single storey rear extension, 4.1m in depth, 3.0m in height.”
Section 02
Decision
The appeal is allowed and prior approval is not required under the provisions of Article 3(1) and Schedule 2, Part 1, Class A, paragraph A.4 of the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) for a single storey rear extension, 4.1m in depth, 3.0m in height, at [site address] , Perivale, Ealing, [postcode] in accordance with the terms of the application, Ref 241563PALHE.
Section 03
Main Issue
The main issue is whether the proposed development would be permitted development under Schedule 2, Part 1, Class A of the GPDO.
Section 04
Reasons
Development is not permitted by Schedule 2, Part 1, Class A of the GPDO if the enlarged part of the dwellinghouse would have a single storey and extend beyond the rear wall of the original dwellinghouse by more than 8 metres in the case of a detached dwellinghouse, or 6 metres in the case of any other dwellinghouse; or exceed 4 metres in height. It goes on to states that development is not permitted if the enlarged part of the dwellinghouse would extend beyond a wall forming a side elevation of the original dwellinghouse, and would exceed 4 metres in height, have more than a single storey, or have a width greater than half the width of the original dwellinghouse.
The Council refused the application citing that due to the proximity of the proposed extension to an existing garage, that cumulatively the development would have a total depth of 10.2 metres and have a width greater than half the width of the original dwelling house. The Council consider that the proposed development would therefore fail to comply with Schedule 2, Part 1, Class A of the GPDO.
The appeal site is a semi-detached, two storey dwelling with a detached garage to its side/rear. The proposed extension would be located to the rear of the property and would be attached to the rear wall of the original dwellinghouse. The proposed extension would extend the full width of the rear elevation with a maximum ridge height of 3 metres and an eaves height of 2.65 metres. The depth of the proposed extension would be 4.1 metres.
I acknowledge that the proposed extension would be in extremely close to the existing garage, with the submitted plans detailing a gap of approximately 100mm. However, neither the GPDO nor the Permitted development rights for householders Technical Guidance (2019) state that where extensions are in close proximity to an outbuilding that their measurements should be combined. Additionally, they do not require extensions to be located a certain distance away from outbuildings for them to be permitted development.
The appellant has confirmed that the extension would remain separate from the existing garage. The submitted plans, which are drawn to scale and annotated with these measurements provide sufficient clarity to demonstrate that the proposed development falls within the permitted development allowances.
There is no dispute between the parties that the proposal would comply with the remaining parts of the Order.
Accordingly, I therefore find that the proposed development would comply with the conditions and limitations set out in Schedule 2, Part 1, Class A of the GPDO.
Section 05
Conditions
[name].3. of Part 1, Class A sets out the conditions subject to which development is permitted by Class A. Of these, only one is relevant namely, that the materials used in any exterior work must be of a similar appearance to those used in the construction of the exterior of the existing dwellinghouse.
[name].4.(11) further sets out that where prior approval is not required the development must be carried out in accordance with the information provided with the application unless the local planning authority and the developer agree otherwise in writing.
Section 06
Conclusion
For the reasons given above, I conclude that the proposed development would constitute permitted development under Schedule 2, Part 1, Class A of the GPDO for which prior approval is not required. Therefore, the appeal is allowed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 568No official casework-database value to compare
- Extracted decision date · page 1
- 11 December 2024Matches the official casework database
- Extracted site visit dates
- 27 November 2024 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3346895
- Application reference
- Not recorded
- Lead case reference
- Not recorded
- Planning authority
- London Borough of Ealing
- Planning authority code
- E09000009
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Other minor developments
- Appeal type reason
- 1. The decision of the LPA refusing/refusing in part to grant a certificate of lawful use or development
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 1
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Allowed
- Decision category
- Allowed
- Received date
- 24 June 2024
- Valid date
- 3 July 2024
- Start date
- 19 August 2024
- Planning authority decision date
- Not recorded
- Appeal decision date
- 11 December 2024
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 61667
- First seen
- 20 August 2026 at 14:24
- Last seen
- 20 August 2026 at 16:28
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:25
- Record updated
- 24 August 2026 at 16:21