Skip to main content
Official casework recordAllowedCurrent release

Appeal 3347780

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

6 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

the construction of a part 1, part 2 storey rear extension and associated external works.

  1. Section 02

    Decision

    The appeal is allowed and planning permission is granted for the construction of a part 1, part 2 storey rear extension and associated external works at [site address] , Eltham, [postcode] in accordance with the terms of the application, Ref 24/0970/HD, and the plans submitted with it, subject to the following conditions:

    The development hereby permitted shall begin not later than 3 years from the date of this decision.

    The materials used in the construction of the external surfaces of the development hereby permitted shall match those used in the existing house.

  2. Section 03

    Main Issue

    The main issue in this case is the effect of the proposals on the character and appearance the original dwelling.

  3. Section 04

    Reasons

    The appeal site is a two-storey semi-detached dwelling located on the northern side of Eltham Park Gardens, Eltham. The surrounding area is predominantly residential, mainly consisting of semi-detached houses of similar design, scale, and appearance. The proposed development is confined to the rear.

    At the rear, there is a single storey rear outrigger with a mono-pitched roof abutting the shared boundary with the attached house at No.39. The appeal dwelling and its neighbours are developed on slopping land, so that the main rear garden area drops down markedly from the ground floor level of the house and its patio area at the rear. There are steps from the patio to the lower garden.

    In respect of rear extensions, the relevant planning guidance is set out in the Council’s Urban Design Guide Supplementary Planning Document (2023) (SPD). [name].3.3 of that document advises that all rear extensions are required to respond appropriately to the scale of the existing building and the size of the garden. This principle also sets out that a 3.6m projection from the rear is typically considered appropriate in [name]. With regard to roof forms for single storey rear extensions, section i.91 of the SPD sets out that a flat roof form is generally preferred as it helps to reduce the overall bulk and impact of the extension. Section i.91 of the SPD states that “Careful consideration needs to be given to the relationship with the first-floor windowsill. Generally, the roof line of the extension should be 300mm below the 1st floor windowsill [...].”

    The council accepts that the single storey element with a depth of 3.25 would not exceed the recommended depth of 3.6m, and its flat roof would have a maximum height of 3.5m. The criticism that underlies the refusal reason is that, when viewed against the backdrop of the original dwelling, sitting on a higher level than the rear garden, the extension would appear as a disproportionate and bulky addition, and that the excessive height of flank walls and rear elevation, in conjunction with the raised patio area, would exacerbate the dominance of this structure. However, the council accepts that single storey element would maintain a sufficient distance (0.6m) between its roof line and first-floor windowsills, in line with the SPD.

    Having viewed the property from the lower rear garden area, I can see that the house, its existing outrigger and patio, dominates the outlook from that garden to a greater extent than is normal on level ground. It is only because of the falling levels that the proposed ground floor extension has the degree of dominance. That relationship is inevitable, and the appearance of the extension as a result, within this physical relationship, does not make it unacceptable.

    Turning to the first-floor element of the proposed rear extension, constructed centrally above the ground-floor element, would be relatively modest in scale. The depth would be limited to 2.5m and the width to 3.3m. Sufficient separation distance from both shared boundaries would exist. The ridge of the proposed dual pitched roof would sit well below the original ridgeline, and its eaves below the line of the eaves of the existing roof. Since it would not be visible from the public domain, any perceived lack of adherence of its gabled roof to the existing roof’s hipped roof form would be minor, and not decisivel in the planning judgement. Furthermore, its rear façade would be set in from the rear elevation of the ground floor element.

  4. Section 05

    Overall conclusion

    My conclusion on the appeal proposal, in the light of my reasoning above, is that it would have a satisfactory visual relationship with the original dwelling and would not detract from its character and appearance. For these reasons it would conform with Policy D3 of the London Plan (2021), Policies DH1and DH(a) of the Royal Greenwich Local Plan: [name] with [name] (2014), and the Council's Urban Design Guide - Supplementary Planning Document (2023). Therefore the appeal will be allowed.

  5. Section 06

    Conditions

    The statutory condition that provides a time limit on the start of development must be imposed. In addition, the council has suggested 2 conditions in the event that the appeal is upheld. I have considered these in the light of Planning Practice Guidance. The first is that the materials shall match those of the existing house. I consider that this is necessary to ensure the satisfactory relationship of the new development with the existing. The second suggested condition is that the development shall be carried out in accordance with the plans. This is necessary for clarity and the avoidance of doubt as to the development permitted, but can be dealt with in the terms of the permission itself.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 129No official casework-database value to compare
    Extracted decision date · page 1
    28 January 2025Matches the official casework database
    Extracted site visit dates
    15 January 2025 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3347780
Application reference
24/0970/HD
Lead case reference
Not recorded
Planning authority
Royal Borough of Greenwich
Planning authority code
E09000011

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
26 m²
Number of residences
1
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Allowed
Decision category
Allowed
Received date
9 July 2024
Valid date
12 July 2024
Start date
23 July 2024
Planning authority decision date
22 May 2024
Appeal decision date
28 January 2025

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
63585
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:28
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21