Skip to main content
Official casework recordDismissedCurrent release

Appeal 3352834

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

4 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

retention of loft conversion alterations relating to side dormer, rear facing first floor window and first floor rear extension height.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    [name]

    The Council’s concerns relate to the side dormer window element of the proposal. There are no objections to the rear facing first floor window and the height of the first floor rear extension. There are no reasons to disagree.

    This decision focuses on the matter in dispute and the main issue therefore is the effect of the side dormer window on the character and appearance of the host property and the surrounding area, including whether it preserves or enhances the character or appearance of the St Stephen’s Conservation Area (the Conservation Area) and its effect on the significance of the designated

  3. Section 04

    Reasons

    In summary and having regard to the St Stephen's Conservation Area Appraisal, I consider that the character of this Conservation Area can be characterised by its good quality late Victorian detached and semi-detached villa-style residential properties on generally spacious plots, together with [name] at its north end. The houses display a wide range of architectural styles typical of the late nineteenth century and there is design variety at an individual property level. However, the area’s common design features create a cohesive whole and give the area its preserved nineteenth century appearance. The east side of [address] has experienced fewer alterations than the west side. Views and focal points within the Conservation Area are long vistas along the tree-lined streets, with some vistas punctuated by the landmark tower of [name].

    It is important to retain the late Victorian character and appearance of the Conservation Area through sensitive development which preserves the authentic historic character of individual houses, their group and the wider street scene in terms of design and materials. Unsympathetic alterations can harm the overall cohesion of a conservation area.

    Planning permission was granted by the Council for the ‘erection of a rear and side roof extension and a part first floor extension to the rear of the house’ in April 2022 (ref 00992/56/P6). Works were not carried out fully in accordance with the planning permission. The appeal application was submitted to regularise matters. Accordingly, the appeal proposal seeks retrospective planning permission for development that has already been carried out.

    The original planning permission indicated that the side dormer was to be set well within the hipped roof slope, being set down from the ridge and set up from the eaves. However, as constructed, the dormer is taller and narrower, extending down from the roof ridge to close to the eaves line. This has resulted in a disproportionately large, tall and bulky dormer which fails to respect the design and profile of the original roof slope in a subordinate manner. Furthermore, it does not comply with the relevant design guidance set out in the [name] (the SPD).

    Due to its overall scale, design and the extent of its projection from the roof, I conclude that the constructed side roof dormer results in an unsympathetic and visually obtrusive development which harms the overall appearance and proportions of the original house and the character and appearance of the surrounding area. The dormer is prominent in the important vista along [address] and fails to preserve or enhance the character or appearance of the Conservation Area. The dormer window harms the significance of the designated heritage asset. I conclude that this harm to significance is less than substantial.

    In accordance with National Planning Policy Guidance, ‘where a development proposal will lead to less than substantial harm to the significance of a designated heritage asset, this harm should be weighed against the public benefits of the proposal including, where appropriate, securing its optimum viable use.’ The height of the dormer was increased to accommodate the height of the occupants of the appeal property, to improve access to the loft, to allow the use of a standard sized door and to enable more of the existing first-floor accommodation to be retained. However, these are private, not public, benefits of the proposal and they do not outweigh the less than substantial harm to the significance of the Conservation Area. Whilst the current occupiers require additional accommodation, the appeal proposal is not necessary to secure the optimum viable use of the appeal property as a home. In any event, an alternative dormer extension has already been approved.

    As the appellant notes, dormer windows exist in the street scene, including on the front elevations of nearby houses. Their presence appears to be a factor in the granting of planning permission for the original side dormer window. The principle of a side dormer window on the appeal property is not a matter in dispute. However, the design and location of the constructed dormer window does not reflect other dormer windows within the visual context of the appeal property. But in any event, the appeal proposal has been determined on its own individual merits.

    For the reasons set out above and having regard to all other matters raised, I conclude that the erected side dormer is contrary to policies CC1 (Context and Character), CC2 ([name] and Architecture), CC4 (Heritage), SC7 ([name] and Alterations) of the adopted Local Plan (2015) and the design guidance within the SPD. Accordingly, the appeal is dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 322No official casework-database value to compare
    Extracted decision date · page 1
    27 December 2024Matches the official casework database
    Extracted site visit dates
    30 November 2024 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3352834
Application reference
P/2024/1018
Lead case reference
Not recorded
Planning authority
London Borough of Hounslow
Planning authority code
E09000018

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
20 m²
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
30 September 2024
Valid date
30 September 2024
Start date
21 October 2024
Planning authority decision date
11 September 2024
Appeal decision date
27 December 2024

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
62249
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:28
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21