Skip to main content
Official casework recordSplit DecisionCurrent release

Appeal 3353050

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

11 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

construction of a rear extension above two-storey outrigger; construction of a dormer roof extension to main rear roof including raising the ridge and parapet wall height, together with removal of chimney and antenna, installation of two roof lights to front roof slope and soil and vent pipe; alterations to rear and side fenestrations and installation of timber decking steps within rear garden; installation of external insultation on the rear and side elevations and installation of a heat pump within front garden.

  1. Section 02

    Decision

    I am issuing a split decision. The appeal is dismissed insofar as it relates to installation of an air source heat pump within the front garden.

    The appeal is allowed and planning permission is granted for construction of a rear extension above two-storey outrigger; construction of a dormer roof extension to main rear roof including raising the ridge and parapet wall height, together with removal of chimney and antenna; installation of two roof lights to front roof slope and soil and vent pipe; alterations to rear and side fenestrations and installation of timber decking steps within rear garden; installation of external insultation on the rear and side elevations, at [site address] , Walthamstow, London [postcode] in accordance with the terms of the application, Ref 241483, subject to the following

  2. Section 03

    conditions:

    The development hereby permitted shall begin not later than three years from the date of this decision.

    The development hereby permitted shall be carried out in accordance with drawing numbers 10HR.010; 10HR.015; 10HR.030; 10HR.040; 10HR.050; 10HR.060 [name]; 10HR.065; 10HR.080; 10HR.130; 10HR.140; 10HR.150; 10HR.200 [name]; 10HR.205; 10HR.300; Location Plan (PP-13142778v1), [name] (VELFAC 200 alu), except in respect of the air source heat pump shown on plan numbers 10HR.130; 10HR.200 [name] and 10HR.300.

    Notwithstanding the approved plans, details/samples of the materials to be used in the construction of the external surfaces of the development hereby permitted shall be submitted to and approved in writing by the local planning authority prior to their installation on site. The development shall be carried out in accordance with the approved details/samples.

  3. Section 04

    Main Issue

    The Council issued four reasons for refusal, but each relates to the visual impact of various elements of the proposal. Therefore, the main issue in respect of each element is the effect on the character and appearance of the area.

  4. Section 05

    Reasons

    The appeal relates to a mid-terraced dwelling standing two storeys over basement at the front and three storeys at the rear. It occupies a confined site that widens slightly towards the rear, with existing lower and upper ground rear extensions standing at angles to the main rear wall. Behind the site are expansive allotments.

  5. Section 06

    Roof and [name]

    The proposed rear dormer would sit between the higher and deeper parapet wall of No 12 on one side, which already has a large rear dormer, and the lower parapet wall with No 8, which would be built up and out to enclose the proposed structure. It would include a large picture window to the rear, two rooflights to the front roof slope and an upward facing rooflight to the centre of the flat roof section.

    The Council’s Residential Extensions and Alterations Supplementary Planning Document (2010) sets out that dormer windows should be of appropriate proportions and relate well to the existing windows of the original house. The dwelling forms part of a long run of houses backing onto the allotments. Most of these have not undergone dormer extensions, but there are a small number of prominent examples of substantial additions infilling the roof and extending out over the rear closet wings. The immediate group of three dwellings at Nos 8, 10 and 12 also differ in their height, shape and massing from others, reflecting the irregular, triangular section of land in which they are situated.

    The proposed dormer would infill the whole roof slope, but would sit against the deeper parapet wall to No 12 and would be set well back from the proposed additional storey to the rear closet wing, the height, position and proposed materials of which would make it the more prominent element of the proposal. As a result, the overall dormer massing and the picture window would have less prominence in views from the allotments at the rear in comparison with the dormer at No 12 which is further rearward and fully visible due to the rear wing of that dwelling being offset to the side. Moreover, the dormer would not appear disproportionate in size when considering the overall height of the dwelling and the additional, more prominent massing proposed to the rear wing.

    The dormer would sit higher than, but well back of, the tall, deep closet wing to No 8 on the other side, which would provide partial screening of the dormer in views from ground level. Although the allotments are an expansive area, longer views of the appeal site from within them are screened from many angles by a copse of trees nearby. Where the rear elevation is visible, it would be seen in context with the varied massing to the rear of this group of three, including the dormer window to No 12 and the similar closet wing to No 8. In this context, the proposed rear dormer and closet wing extensions would integrate with the existing built form in an acceptable manner.

    The proposed rooflights to the front would reflect numerous examples visible to properties on the surrounding streets. The rooflight to the flat part of the roof would be a small projection that would not appear prominent in views from street level and would not disrupt the overall appearance of the dwelling.

  6. Section 07

    [name]

    The Council raises concern in respect of the proposed application of insulated render to the rear elevation of the building, citing a lack of detail in respect of thickness, colour and the relationship to the window openings. The section plans before me show a minor additional thickness to the existing rear closet wing, but that the overall depth of the extension would align with the rear wall of No 12 with only a very modest additional depth attributable to the render. As the rear windows are to be replaced, it is reasonable to consider that they would be fitted to achieve an appropriate depth of reveal taking the thickness of the insulation and render into account. There are also sufficient examples of rendered and painted walls across the rear elevations of neighbouring dwellings, including the side wall of the closet wing to No 12, that the proposed rendered finish would not appear uncharacteristic or disruptive of a uniform palette of materials.

    The Council has not otherwise objected to the proposed alterations to the rear fenestration, or the installation of timber decking to the rear courtyard. Given the aforementioned variety to the rear elevations along the terrace, I am satisfied that the proposed changes would integrate with the pattern of development. However, given the cumulative extent of façade changes proposed, a condition specifying the proposed external materials is necessary in the circumstances to ensure a satisfactory appearance is secured.

  7. Section 08

    Air Source Heat Pump/[name]

    At the front, it is proposed to install an air source heat pump (ASHP) within the small front courtyard. The courtyard is presently used for bin storage in common with other properties in the street. The front boundary walls are low, allowing clear views into the front courtyard, although the site benefits from a taller dividing wall with the courtyard of No 8 compared to others in the street.

    The plans indicate that the ASHP would be located against this taller wall to the side of the courtyard and would not be seen in views from the [address] side; however it would be plainly visible in views from the other side and when in front of the dwelling. Although the elevation drawing suggests that the ASHP would not obstruct the front windows, the specification sheet indicates side and rear air intakes but does not clarify whether certain clearances are required for this, and thus it is unclear if the proposed position tight to the side wall of the courtyard is achievable. Even in the proposed location, the ASHP would include necessary electrical connections and pipework and would have an intrusive, utilitarian presence immediately next to the public realm. The addition of necessary storage of three wheelie bins in the same limited space, whilst physically achievable, would create a cluttered and incongruous appearance to the front of the dwelling.

    The appellant points to the installation of an ASHP constituting permitted development under Schedule 2, Part 14, Class G of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended), but highlights that the ASHP must be installed more than 1 metre from the boundary of the curtilage of the dwellinghouse, which would result in the ASHP sitting next to the front porch and in front of the ground floor window, with no practical location identified within the rear courtyard. I accept that there is a potential fall-back position in this respect, but it is one that is, by the appellant’s own admission, inferior in design terms and I am doubtful that the appellant would proceed to install the ASHP in a more intrusive location next to the front entrance. As such, I afford little weight to the fall-back position as a realistic alternative and it does not lead me to conclude that the proposed location would be acceptable as a less harmful option.

    The Council’s concerns with the location of the refuse bins is predicated on the installation of the ASHP. Should this not be installed, the bins would continue to be stored in the courtyard in the same manner as other properties in the street, but without the harmful, cluttered appearance that would result from the ASHP being added to the front of the property.

  8. Section 09

    Conclusions on Main Issue

    For the reasons set out, I conclude that the proposed rear and dormer extensions, rooflights, soil and vent pipe, alterations to rear and side fenestrations, removal of chimney and antenna, installation of external insultation on the rear and side elevations and timber decking steps within rear garden would cumulatively preserve the character and appearance of the area, in accordance with Policy 53 of the [site address] Local Plan Part 1 (2024) and Policy D4 of the London Plan (March 2021), which together require development to achieve high quality design that reinforces and/or enhances local character and distinctiveness, taking into account factors including existing patterns of development, townscape, urban form and grain, building typologies and architecture. However, as set out above, the ASHP would cause significant harm to the character and appearance of the area, contrary to the aims of these same policies.

  9. Section 10

    Other Matters

    The Council did not refuse the application in respect of other matters, including the living conditions of neighbouring occupants. On the evidence before me, I have no reasons to conclude otherwise.

  10. Section 11

    Conclusion

    For the reasons set out, I conclude that the proposed ASHP would result in harm to the character and appearance of the area, in conflict with the development plan, to which I afford significant weight. I recognise that the ASHP would deliver improvements in energy efficiency and this would be a benefit of the proposal. However, the scale of this would be limited and would not outweigh the development plan conflict so as to justify granting planning permission. Therefore, I conclude that this part of the appeal should be dismissed.

    However, I conclude that other proposed works accord with the development plan, taken as a whole, and as these are physically and functionally severable from the proposed ASHP, I conclude that this part of the appeal should be allowed, subject to a condition setting out the approved plans, to provide certainty, and a condition specifying the proposed external materials to ensure a satisfactory appearance.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 426No official casework-database value to compare
    Extracted decision date · page 1
    7 March 2025Matches the official casework database
    Extracted site visit dates
    18 February 2025 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
3353050
Application reference
241483
Lead case reference
Not recorded
Planning authority
Waltham Forest London Borough Council
Planning authority code
E09000031

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
1. Refused planning permission
Appeal reason
Refusal
Type detail
Planning Appeals - Full
Jurisdiction
Transferred
Link status
Not Linked

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
Not recorded
Floor space
Not recorded
Number of residences
0
Site in Green Belt
No
Agricultural holding
No
Affects setting of a listed building
Not recorded
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Split Decision
Decision category
Split decision
Received date
2 October 2024
Valid date
2 October 2024
Start date
25 October 2024
Planning authority decision date
20 August 2024
Appeal decision date
7 March 2025

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
No
Bespoke
No
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
Not recorded
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Horizon
Dataset status
Current release
Catalogue record ID
65876
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:28
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21