Appeal 3357745
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
6 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
described as ‘Installation of air source heat pump.’
Section 02
Decision
The appeal is dismissed.
Section 03
Main Issue
The main issue is the effect of the proposed Air Source Heat Pump (ASHP) on the living conditions of the occupiers of the adjacent properties on [address].
Section 04
Reasons
The appeal site comprises a semi-detached property situated in a residential area with a general uniformity of property types. To the east (rear) of the site lies an area of open space. To the south is the attached neighbouring semi-detached property (No. 17). The proposal involves installing the apparatus on the rear (eastern) elevation of No. 15.
The UK Government are actively supporting the transition to more renewable forms of domestic heating in line with their commitment to achieve [name] by
ASHPs are a key technology for achieving net zero emissions from domestic heating and helping to build the UK’s energy resilience and security.
The General Permitted Development Order (GPDO) allows for air source heat pumps (ASHPs) under Part 14, Class G, which pertains to domestic premises subject to certain limitations and conditions. According to the current [name] (MCS) - Planning Standards, an air source heat pump (ASHP) must be certified with a sound level not exceeding 42dB to qualify as ‘permitted development’. The ASHP proposed in this case has a noise rating of 43dB. This is detailed in the MCS 020 – [name] submitted with the application and provided in the Council in evidence.
The appellant’s position is that the noise footprint of the ASHP, as it related to impact on neighbouring properties, is within an acceptable range for a residential area such as where the appeal site is located.
The Environmental Health Officer (EHO) in responding to the consultation on the planning application did not offer support for the proposal. They identified that at this location they would expect noise levels to be 35dB at the nearest neighbours and referred to Chartered Institute of Environmental Health and Institute of Acoustics guidance in this regard.
This guidance ‘Heat Pumps Professional Advice Note – November 2022’ recommends that where it is practical to do so, sound rating levels do not exceed 35dB at any noise sensitive façade of neighbouring residential premises. Regardless, it is recommended that the sound rating level should not exceed 40dB.
In response to this, I note that the submitted MCS 020 – [name] identifies the noise data recordings relate to the sound power level of the operating ASHP. This results in a calculation of 43dB which is higher than the recommended level.
At the site visit I was able to see that there are outbuildings attached to the main dwelling which will likely be effective acting to screen the properties to the north from noise associated with the ASHP. In this regard I am satisfied that the proposed ASHP will not have a detrimental impact on the living conditions of the properties to the north due to noise.
The large open space at the rear of the property means there are no nearby residential dwellings that could be negatively affected. However, because this area remains undeveloped, background noise levels are likely to be lower than they would be in a more built-up environment. As a result, any noise generated by the ASHP is likely to stand out more in this setting.
The appellant has not submitted an assessment of anticipated noise levels at No.17, the adjacent property. Although vegetation exists within and near the boundary of the appeal site, no measures have been identified or proposed to mitigate noise emissions from the ASHP in relation to No.17. Furthermore, no other factors have been presented that would indicate the proposed noise level of 43dB from the ASHP would be acceptable or justified.
I have also considered the Council’s Environmental Health Officer’s suggestion that alternative units, sound control engineering measures (such as proprietary acoustic enclosures or silencer packs), and locations within the property boundary should be considered. However, it would not be appropriate to require the installation of such sound control engineering measures through a planning condition. In this respect, I agree with the Council’s position and consider that such a condition would not be reasonable or enforceable, as it could conflict with the plans submitted with the application or the description of the proposed development. For example, the construction of screening or enclosures, which may themselves need planning permission, and alterations to the external appearance of the unit could conflict with the description of development and submitted plans.
For the same reason, while I welcome the appellants proposal to engage post installation monitoring with a view to addressing issues should they arise, any necessary works could themselves require planning permission. A condition requiring this monitoring with potential requirement for remedial action would also fail the rest of reasonableness, as it could potentially require the removal of the ASHP if noise levels were to be identified as unacceptable. This would be when the ASHP is the properties only source of heating.
Overall, while I find that the proposed air ASHP would contribute to energy efficiency, given the site’s circumstances, it would cause harm to the living conditions of the occupants of the adjacent residential property (No.17). It therefore fails to meet the requirements of Policy HDG2 of the Householder Design Guide Supplementary Planning Document 2012. It also fails to comply with the relevant parts of the [name] (as amended by the [name] 2019) Leeds Local Plan Policy P10, saved Leeds Unitary Development Plan Review (2006) (the [name]) Policies GP5 and BD5. Amongst other things, these require that all new buildings should be designed with consideration given to both their own amenity and that of their surroundings. The failure to comply with the provisions of the development plan is not outweighed by any other factors.
Section 05
Other Matters
[name] EN1 and EN3 advocate for measures to mitigate climate change and promote renewable energy. While these policies primarily apply to major developments, the council has declared a climate emergency, emphasising the importance of transitioning to a low-carbon future. Section 14 of the National Planning Policy Framework (the Framework) highlights the planning system’s role in supporting this transition. This has had some limited weight in my determination of the appeal and is insufficient to overcome my conclusions with regard to the main issue considered above.
Section 06
Conclusion
For the reasons identified above, the proposal conflicts with the development plan as a whole, and material considerations do not indicate that the appeal should be decided other than in accordance with it. Therefore, the appeal is dismissed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 5323No official casework-database value to compare
- Extracted decision date · page 1
- 12 June 2025Matches the official casework database
- Extracted site visit dates
- 29 April 2025 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3357745
- Application reference
- 24/05933/FU
- Lead case reference
- Not recorded
- Planning authority
- Leeds City Council
- Planning authority code
- E08000035
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 18 December 2024
- Valid date
- 18 December 2024
- Start date
- 7 January 2025
- Planning authority decision date
- 27 November 2024
- Appeal decision date
- 12 June 2025
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 71091
- First seen
- 20 August 2026 at 14:25
- Last seen
- 20 August 2026 at 16:28
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:25
- Record updated
- 24 August 2026 at 16:21