Appeal 3362877
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
6 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
Front and side two storey extension to dwelling.
Section 02
Decision
The appeal is dismissed.
Section 03
Main issues
Covering the 3 reasons for refusal on the Council’s decision notice, I consider the main issues to be the implications of the proposed development, in terms of its siting and scale, for the character and appearance of the surrounding area, for the amenity of the occupants of [address], and for car parking at the host property.
Section 04
Character and appearance
Paired with no. 40, the appeal property is a semi-detached, 2-storey house. The residential layout found along the northern side of [address], where the appeal property is situated, is characterised by semi-detached and detached houses which follow a fairly regular building line and do not exhibit any 2-storey forward additions to their original built form. This local pattern of development is important in maintaining a sense of place and makes a positive contribution to the local character and appearance of the area.
The principle of extending the property and adapting it to meet the changing needs of the current occupants is not at issue. However, I consider that the extension, owing to its prominent forward siting and notable scale, would not sit comfortably in this street scene. Its protrusion forwards and sideways over 2 storeys would be wholly at odds with the built form of other nearby properties and would result in an incongruous interruption to the linear pattern and spacing of development here.
The failure to respect the context of the site and the disruption to the prevailing pattern of development would harm the character and appearance of the surrounding area. In so doing, the proposal would eschew the requirements for good design within Policy LP16 of the Peterborough Local Plan 2019 (LP) and Policy GNP3 of the Glinton Village Neighbourhood Plan 2021 (NP). Good design is also a cornerstone of the National Planning Policy Framework.
The appellant has submitted a photograph of an allegedly comparable development. I identified this to be at [address]. This is an isolated example of a similar development on the same residential estate. It is some distance away from the appeal site and not part of the same street scene. I saw that as the extension at [address] does not overlap the side of the house, the 2-storey front projection there is not as wide as the one proposed at [site address] . Still, it is not a good example to follow as the extension looks out of place in the [address] street scene. In any event, it is an established planning principle that each case is considered on its own merits. Moreover, there is no evidence before me about the planning history of this other case, so I do not know if that extension was approved under the same and current development plan policies. Amenity of the occupants of [address]
Policy LP17 of the LP and Policy GNP3 of the NP seek to ensure that new development does not result in an unacceptable impact on the amenity of existing occupiers of any nearby properties. The Council’s sole concern on this issue was with the potential for overbearing and overshadowing impacts upon [address].
The maximum projection of the proposed extension from the forwardmost ground floor front wall of the appeal property would be 1.4m. Whilst the extension would reach across so as to be only 790mm from the common boundary with no. 44, like the appellant I am not convinced it would cross the 45 degree line taken in a horizontal plane and measured from the centre point of the neighbour’s nearest primary habitable room front windows which serve a living room below a bedroom. Such a 45 degree code is often used to determine the acceptability or otherwise of extensions in terms of their overshadowing or overbearing impacts.
There is a narrow east-facing side light in the front bay window to the ground floor living room at no. 44. This would directly oppose the blank side wall of the proposed extension but it is not the principal front window to that room. So, whilst there may be some diminution in the daylight and morning sunlight reaching and the outlook from that section of the bay window and some reduction in the existing levels of privacy from the narrowing of the passageway alongside no. 42, I consider that the living conditions in that room would not, for any reason, be so unacceptably impacted as to bring the scheme into conflict with LP Policy LP17 and NP Policy GNP3.
Section 05
Car parking at the host property
There is a requirement for a minimum of 2 on-plot car parking spaces for dwellings with 3 bedrooms like no. 42, as existing and as proposed to be extended.
The scheme on drawing PL01B seeks to rely on 2 such spaces in the front garden.
The Local Highway Authority (LHA) objected to the application and, according to the [name], said that the site plan on drawing PL01B showed car parking spaces that are not acceptable to the adopted standards. 2
The LHA requires a minimum length of 5m where a car is parked in front of a wall or 6m in front of an entrance doorway or side passageway to allow for safe access to and egress from a property. I agree with the LHA that the 6m distance would be apt in this case on the basis of the general parking layout shown on drawing PL01B.
The basic site plan on drawing PL01B is not annotated with detailed survey measurements of the depth or width of the front garden area. There is little more than 6m between the forwardmost ground floor wall of the house and the back edge of the public footway. Drawing PL01B would suggest that there is 7m or more between them. This is not the case. If the front extension is to be 1.4m in depth from the forwardmost ground floor front wall of the house as stated on the plans, then the LHA’s estimate that the remaining driveway would be only 4.65m long seems to me to be broadly accurate.
This would not meet the 5m or 6m standards. The likelihood is that vehicles would be parked overhanging the public footway putting pedestrians in danger and/or there would be an increase in the number of vehicles parked on the road causing obstructions to the safe passage of other road users. Thus, the proposal does not make appropriate or deliverable car parking provision at the host property in accordance with adopted standards. This puts the scheme at odds with the parking provision requirements in LP Policy LP13.
Section 06
Concluding comments
My findings on the main issues relating to the character and appearance of the surrounding area and car parking at the host property are decisive to the outcome of this appeal. There is conflict with the development plan. The harm cannot be mitigated by the imposition of planning conditions and it is not outweighed by other material considerations or by my findings on the main issue relating to the amenity of the occupants of [address].
For the reasons given above and taking into account all other matters raised, I conclude that this appeal should not succeed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 807No official casework-database value to compare
- Extracted decision date · page 1
- 26 June 2025Matches the official casework database
- Extracted site visit dates
- 11 June 2025 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3362877
- Application reference
- 24/01482/HHFUL
- Lead case reference
- Not recorded
- Planning authority
- Peterborough City Council
- Planning authority code
- E06000031
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Planning Appeals - Full
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 22 March 2025
- Valid date
- 22 March 2025
- Start date
- 26 March 2025
- Planning authority decision date
- 28 January 2025
- Appeal decision date
- 26 June 2025
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 71892
- First seen
- 20 August 2026 at 14:25
- Last seen
- 20 August 2026 at 16:28
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:25
- Record updated
- 24 August 2026 at 16:21