Appeal 3368067
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
5 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
the erection of a single-storey extension to the rear.
Section 02
Decision
The appeal is dismissed.
Section 03
Main Issue
The main issue in this case is the effect of the proposed extension on the living conditions of the occupiers of No [address] of overshadowing and outlook.
Section 04
Reasons
No 43 is a semi-detached bungalow situated at the western end of [address], which is a cul-de-sac. It is attached to No 41, and lies to the north of that property. No 43 has been extended to the north and west with single-storey elements to provide additional living accommodation. To the rear of the original property is an open area alongside the boundary with No 41 which continues around behind the original bungalow and its existing extension, and which leads onto an extensive rear garden. The proposed development would involve the construction of an L-shaped extension, wrapping round the existing buildings and filling the gap between those buildings and the boundary with No 41. Its maximum depth would be 7 metres along the boundary, and it would be 3 metres high with a flat roof.
Policy ENV8 of the Council’s Local Plan indicates that where development is considered to be appropriate but may still have impacts on certain specified environmental considerations, the Council will consider the use of conditions or planning obligations to ensure any appropriate mitigation or compensatory measures are secured. These considerations include the need to respect living conditions of existing neighbouring residential properties in relation to overshadowing, sunlight, daylight, and outlook.
[address] Extensions Supplementary Planning Document (SPD) indicates that any rear extensions should not over-dominate the neighbouring properties. For a single-storey extension along the shared boundary with an adjoining house, an extension of 3 metres may be allowed where this is an extension to the original rear elevation. This may be increased if the immediately adjoining property also has an extension along the shared boundary. In addition, the height of an extension will be a factor in assessing the impact on neighbours’ amenities. The 45 degree code in relation to neighbouring properties will be applied, such that extensions should be designed so as not to cross the 45 degree line taken in a horizontal plane and measured from the centre point of the neighbour’s nearest primary habitable room window.
In this case, the proposed extension would run along the boundary with No 43 for 7 metres, with a height of 3 metres. There is an existing single-storey extension along the boundary at No 43, but this is only 1.6 metres deep. Beyond this extension, some 3 metres in from the boundary, is another rear extension projecting approximately a further 2 metres, with a conservatory beyond that. The boundary fence between the two properties is some 1.8 metres high for the first few panels, and then drops to around 1.5 metres in height.
The appeal property is situated to the north-west of No 41. As a result, the extension would have some limited impact on sunlight in the late afternoon, but it would not result in significant overshadowing. However, it would project 5.4 metres beyond the rear elevation of the closest extension at No 41, at a height of 3 metres. In the rear elevation of the extension at No 41 is a habitable room window, and the proposed development would, therefore, break the 45 degree code by a significant amount. In addition, it would result in a significant length of unbroken brick wall for over 5 metres beyond the rear elevation at No 41, and this would be at a height over 1 metre above the boundary fence. I consider that this combination of height and depth would represent an over-dominant and overbearing outlook for the occupiers of No 41.
The appellant contends that the boundary fence could be raised to a height of 2 metres without express permission, and that the extension at No 41 is already subject to a corridor effect due to the other extensions at that property. In addition, the gardens at both properties are open and extensive. I acknowledge that the land at the rear of the bungalows is extensive. However, there is currently a gap of around 3 metres between the existing building at the rear of No 43 and the boundary. The proposed extension would run along the boundary itself for a further 5.4 metres. This, together with the 1 – 1.2 metre additional height that would result from the proposal, would result in an oppressive outlook from the rear of No 43.
Section 05
Conclusion
In conclusion, I find that the proposed extension at No 43 would result in some overshadowing to the property at No 41, but that this would only be limited. However, by reason of the combination of its length and height, and the fact that it would significantly break the 45 degree code, the extension would result in an overbearing and oppressive outlook to the occupiers of No 41. On this basis, it would conflict with Policy ENV8 of the LP, and with guidance on rear extensions in the SPD. Accordingly, I dismiss this appeal.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 239No official casework-database value to compare
- Extracted decision date · page 1
- 12 August 2025Matches the official casework database
- Extracted site visit dates
- 8 August 2025 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 3368067
- Application reference
- 2025/00134/FULH
- Lead case reference
- Not recorded
- Planning authority
- Warrington Borough Council
- Planning authority code
- E06000007
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- 1. Refused planning permission
- Appeal reason
- Refusal
- Type detail
- Unknown
- Jurisdiction
- Transferred
- Link status
- Not Linked
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- Not recorded
- Floor space
- Not recorded
- Number of residences
- 0
- Site in Green Belt
- No
- Agricultural holding
- No
- Affects setting of a listed building
- Not recorded
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 23 June 2025
- Valid date
- 1 July 2025
- Start date
- 1 July 2025
- Planning authority decision date
- 1 April 2025
- Appeal decision date
- 12 August 2025
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- No
- Bespoke
- No
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- Not recorded
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Horizon
- Dataset status
- Current release
- Catalogue record ID
- 74611
- First seen
- 20 August 2026 at 14:25
- Last seen
- 20 August 2026 at 16:28
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:25
- Record updated
- 24 August 2026 at 16:21