Appeal 6000155
Public case and site metadata stored from the official casework database, including fields that were empty in the source release.
A clearer next step
See how Inspectors approached issues like yours
Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.
- See which issues the decision appears to turn on
- Compare the facts and open the full appeal records
One private comparison
How the refusal review worksOne-off service · No subscription
Similar appeals are evidence to inspect, not a prediction of your outcome.
Official decision document
The decision, section by section
7 sections
Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.
Section 01
Development description
single storey rear extension.
Section 02
Decision
The appeal is dismissed.
Section 03
Preliminary Matters
Under Article 3(1) and Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 as amended (“the GPDO”), planning permission is granted for the enlargement of a dwellinghouse subject to limitations and conditions.
Where an application is made for a determination as to whether prior approval is required for development which exceeds the limits in paragraph A.1(f) but is allowed by paragraph A.1(g) to Part 1, paragraph A.4(3) provides that the local planning authority may refuse the application where it considers that the proposed development does not comply with the conditions, limitations or restrictions that are applicable to such permitted development.
Section 04
Main Issue
The main issue is whether the proposed development would be granted planning permission by Article 3, Schedule 2, Part 1, Class A of the GPDO.
Section 05
Reasons
The appeal site (No 31) comprises a two-storey semi-detached dwelling facing [address]. It contains a single-storey flat roof rear extension and a conservatory attached to the rear of that extension.
Development is not permitted by Schedule 2, Part 1, Class A of the GPDO if, as set out in limitation (j), the enlarged part of the dwellinghouse would extend beyond a wall forming a side elevation of the original dwellinghouse and would have a width greater than half the width of the original dwellinghouse. In relation to a building, the GPDO defines “original” as, amongst other things, a building existing on 1st July 1948, as existing on that date; or if built on or after 1st July 1948, as so built.
The Government’s Technical Guidance1 advises that a wall forming a side elevation will be any that cannot be identified as being a front wall or a rear wall, and that houses will often have more than two side elevation walls. This guidance does not suggest a minimum depth in which a built feature can be considered as a side elevation for the purposes of the GPDO.
A small tiled monopitch roof protrudes above the existing rear extension flat roof and is attached to the main rear elevation of No 31. This monopitch roof is of very similar form to that which is also visible above the adjoining rear extension of No
This suggests that No 31 and No 33 each contained a short side elevation enclosed above by the monopitch roofs, and set in at some distance from the main side elevations of each dwelling.
Given the above context and based on the submitted evidence, and my site visit observations, as a matter of fact and degree I conclude that the proposed extension would project beyond a wall forming a side elevation of the original dwellinghouse.
The limitation (j) width restriction does not solely apply to the part of the extension that extends beyond a side wall of the house. The Technical Guidance clearly advises that where an extension fills the area between a side elevation and a rear wall, then the restrictions on extensions beyond rear walls and side walls will both apply. If a proposed extension extends beyond a side wall and is more than half the width of the original house, it would not be permitted development and an application for planning permission would be required.
Therefore, as the width of the proposed extension is greater than half the width of the original dwellinghouse, it would not comply with limitation (j) and is thus not permitted under the GPDO. As the proposal does not constitute permitted development, for the purposes of this appeal there is no need to formally consult adjoining premises, as this could not change the outcome of this appeal.
Section 06
Other Matters
It is put to me that other nearby Councils allow the removal of a bay to allow permitted development extensions. Be that as it may, I must consider this appeal having regard to the GPDO, its Technical Guidance, the evidence before me and my site visit observations. This purported approach of nearby Councils therefore does not justify allowing this appeal.
Section 07
Conclusion
For the above reasons, the appeal is dismissed.
Planning inspector and document dates
The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.
Appeal Decision
- Extracted inspector · page 1
- Inspector attribution ID 4438No official casework-database value to compare
- Extracted decision date · page 1
- 29 September 2025Matches the official casework database
- Extracted site visit dates
- 13 August 2025 (page 1)
Reference and authority
Official identifiers and the planning authority recorded against this case.
- Case reference
- 6000155
- Application reference
- Y0031.25
- Lead case reference
- Not recorded
- Planning authority
- London Borough of Havering
- Planning authority code
- E09000016
Casework details
The casework, procedure, development and linking details supplied by the official record.
- Casework type
- Householder (HAS)
- Procedure
- Written Representations
- Development type
- Householder developments
- Appeal type reason
- Not recorded
- Appeal reason
- refused
- Type detail
- No Application Type Assocaited
- Jurisdiction
- No Jurisdiction Associated
- Link status
- Not recorded
Site and development
Published appeal-site measurements and planning designations, without the withheld precise location fields.
- Site area
- 0 hectares
- Floor space
- 21 m²
- Number of residences
- Not recorded
- Site in Green Belt
- No
- Agricultural holding
- Not recorded
- Affects setting of a listed building
- Yes
- Historic building grant made
- Not recorded
- Relates to a conservation area
- Not recorded
- Flooding is an issue
- Not recorded
- Site within an AONB
- Not recorded
- Site within an SSSI
- Not recorded
Decision and dates
The published outcome and every imported case date.
- Official decision
- Dismissed
- Decision category
- Dismissed
- Received date
- 8 March 2025
- Valid date
- 8 March 2025
- Start date
- 14 March 2025
- Planning authority decision date
- 14 February 2025
- Appeal decision date
- 29 September 2025
Case administration
Published recovery, call-in, costs and enforcement information for this case.
- Redetermined
- Not recorded
- Bespoke
- Not recorded
- Date recovered
- Not recorded
- Date not recovered or derecovered
- Not recorded
- Call-in date
- Not recorded
- Costs applied for
- No
- Enforcement grounds count
- Not recorded
- Enforcement grounds
- Not recorded
Source and catalogue history
When this record appeared in the rolling official release and when the catalogue stored it.
- Source
- Planning Inspectorate casework database
- Source data system
- Back Office
- Dataset status
- Current release
- Catalogue record ID
- 77086
- First seen
- 20 August 2026 at 14:25
- Last seen
- 20 August 2026 at 16:28
- Removed from release
- Not recorded
- Record created
- 20 August 2026 at 14:25
- Record updated
- 24 August 2026 at 16:21