Skip to main content
Official casework recordSplit DecisionCurrent release

Appeal 6003062

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

7 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

described as single storey front extension incorporating porch. Single storey side to rear extension. Alterations to roof to form end gable and rear dormer. Window in gable end. Rooflights in front roof slope. External alterations (part retrospective).

  1. Section 02

    Decision

    The appeal is dismissed insofar as it relates to the rear box dormer.

    The appeal is allowed and planning permission is granted insofar as it relates to the single storey front and rear extensions, the hip to gable roof alteration and rooflights to front roof slope at [site address] in accordance with the terms of the application, PL/2472/25, and the plans submitted with it, subject to the following conditions:

    The development hereby permitted shall begin not later than 3years from the date of this decision.

    The materials to be used in the construction of the external surfaces of the development hereby permitted shall match those used in the existing building.

    The development hereby permitted shall be carried out in accordance with the following approved plans, drawings: PE-01 REV01, 02 REV01, AB-01 REV01, 02 REV 01, 03 REV 01, 04–[name] 01, PR-01 REV 01,02 REV 01, 03 REV01, BLOCK PLAN scale 1:500 and LOCATION PLAN scale 1:1250 insofar as the drawings relate to those parts of the proposal that are approved.

  2. Section 03

    Main Issue

    I consider the main issue to be the effect on the architectural integrity of the host property.

  3. Section 04

    Reasons

    The appeal property, number [site address] is a two-storey semi-detached dwelling. It is located in a residential street. [name] observed, although extended and altered over time the dwellings nearby have generally, but not exclusively retained their hipped roof form.

    The appellants propose a single storey front extension, single storey side and rear extension, alterations to the roof to form a gable end with a window rear box dormer together with rooflights to front roof slope along with associated external works.

    Alterations to the roof including the gable end, and rear dormer were the subject of a previous appeal to determine whether at the time of the application they constituted permitted development. That appeal Ref: APP/M5450/X/23/3334807 was dismissed. However, this consideration has no weight in respect of my determination of this appeal which I will consider on its own planning merits.

    [name] observed on the occasion of my site visit the proposed single storey front, side and rear extensions together with the new gable end, rear box dormer, roof windows to front roof slope and external alterations have all been undertaken but await external finishes.

    The Council consider that the single storey rear extension would be in keeping with the established pattern of development in the area and is therefore acceptable. Further, it regarded the front extension to be acceptable in the light of other front extensions in the area. The proposed porch, part of the proposed front extension was approved by the local planning authority under its Ref: P/1462/22 and was therefore found acceptable. From what I have seen and read I have not formed a contrary view in respect of these matters.

    From the evidence before me I also note that the Council raise no objection to the proposed gable end roof alteration or the proposed rooflights to the front slope. Based on what I have seen and read I have again not formed a contrary view.

    My attention has been drawn to the Harrow Supplementary Planning Document Residential [name] (2010) (SPD). The advises that amongst other things: roof alterations and dormer windows should complement the original street character and not dominate buildings or impair their proportions or character. Dormers should be subordinate features in the roof, should not overlap or wrap around the roof hips, and should never rise above the ridge. In order to reduce its visual impact, such a rear dormer should be set in at least 1000mm from the edge (or verge) of the roof and 500mm from a shared (party) wall, and 500mm from an adjacent valley on a return roof and set at least 1000mm above the roof eaves.

    Due to the overall scale, size and design of the rear dormer as built it would, in addition to failing to accord with the guidance set out in the Council’s SPD, appear as dominant, bulky and visually incongruous feature here.

    The exposed side of the box dormer and the new gable end would both be open to public view from the street, through the gap between No.1 and No.3. Cumulatively the box dormer and gable end when viewed together would appear bulky and visually unattractive. Accordingly, the box dormer would result in significant visual harm to not only the architectural integrity of the existing dwelling but as an unattractive alien feature in the street scene.

    I conclude in respect of the main issue that the proposed box dormer would fail to accord with the objectives of the National Planning Policy Framework (2024), Policy D3.D (1) and (11) of the London Plan (2021), Policy DM1 of the Harrow Development Management Policies Local Plan (2013) and the adopted Harrow Supplementary Planning Document Residential [name] (2010) as well as Policy GR1 of the Draft Harrow Local Plan 2021-2041 as they relate the quality of design.

  4. Section 05

    Other Matters

    My attention has been drawn to similar box dormers in the surrounding areas. Whatever the background to those cases they are not an appropriate justification for permitting another here.

    The need for accommodation for larger families is noted. However, I do not believe that in this case this consideration outweighs the harm to the architectural integrity of the host property or the character of the wider area that the proposed box dormer would cause.

    The single storey rear extension and the front extension, including the porch, hip to gable alteration and rooflights to front roof slope are not disputed by the local planning authority, and I conclude that they would not cause harm to the either the architectural integrity of the host property or the character and appearance of the area and should therefore be permitted.

  5. Section 06

    Conditions

    To ensure a high quality development, I shall include a condition about the materials to be used in the construction of the external surfaces of the building.

    In the interests of certainty, I shall impose a condition requiring the development to be undertaken in accordance with the approved plans.

  6. Section 07

    Conclusion

    For the reasons given above and having regard to all other matters raised, I conclude that the appeal should be allowed only in part but otherwise dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 1184No official casework-database value to compare
    Extracted decision date · page 1
    2 April 2026Matches the official casework database
    Extracted site visit dates
    11 March 2026 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
6003062
Application reference
PL/2472/25
Lead case reference
Not recorded
Planning authority
London Borough of Harrow
Planning authority code
E09000015

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
Not recorded
Appeal reason
refused
Type detail
Householder
Jurisdiction
No Jurisdiction Associated
Link status
Not recorded

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
0 hectares
Floor space
273 m²
Number of residences
Not recorded
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
Yes
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Split Decision
Decision category
Split decision
Received date
23 December 2025
Valid date
23 December 2025
Start date
13 January 2026
Planning authority decision date
21 November 2025
Appeal decision date
2 April 2026

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
Not recorded
Bespoke
Not recorded
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
No
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Back Office
Dataset status
Current release
Catalogue record ID
86993
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:29
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21