Appeal 6005577

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

8 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

a single and two storey rear extension, loft conversion including a rear facing dormer.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Appeal Procedure

    The site visit was undertaken by a representative of the Inspector whose recommendation is set out below and to which the Inspector has had regard before deciding the appeal.

  3. Section 04

    Main Issue

    The main issue is the effect of the proposal on the character and appearance of the host dwelling and surrounding area.

  4. Section 05

    Reasons for the Recommendation

    The appeal site comprises a two-storey semi-detached dwelling. It is located within a residential area characterised by predominately semi-detached and terraced dwellings that are relatively consistent in terms of their original uniform design and appearance, although several of the properties have rear flat roofed single storey extensions.

    The proposed dormer would be located on the rear roof slope of the dwelling and would therefore not be widely visible within the street scene of [address]. There would, however, be partial views from [address], a block of flats located to the side and rear of the adjoining neighbouring property, which occupies a lower ground level than the appeal property.

    The dormer would also be visible from the rear gardens of neighbouring properties. I observed that the surrounding roofscape remains largely unaltered. In this context, the proposed dormer would appear as a visually discordant feature, at odds with the established pattern of development in the locality.

    The dormer would extend close to the roof ridge and would be set in slightly from the eaves. It would extend almost the full width of the roof slope and would result in a substantial addition to the roof plane resulting in the property appearing top heavy. It would fail to achieve an appropriate degree of subordination to the host dwelling given its scale, siting and design. Whilst the use of matching materials would contribute to assimilating the proposal into the roof space of the host dwelling, these aspects do not overcome the adverse effects outlined above.

    The proposed two-storey rear extension would occupy an existing patio area. It would infill an area to the side of the existing side projection which extends into the rear garden. The flat roof of the proposed two-storey rear extension, which would project above the eaves height of the host dwelling would appear incongruous when viewed alongside the prevailing pitched roofs of surrounding two-storey dwellings. As a result, the extension would fail to integrate successfully with the rear of the host property or with the overall appearance of the semi-detached pair.

    When considered cumulatively, the proposed developments would appear dominant from public viewpoints despite being at the rear, and would significantly alter the original form, character and appearance of the dwelling. The additions would result in a top-heavy, unbalanced and visually incongruous form of development that would appear unduly prominent within its surroundings, particularly when viewed in the context of prevailing roof forms of adjoining and nearby dwellings.

    Given that the dwelling forms part of a semi-detached pair, the proposed dormer and two-storey flat roof extension would disrupt the visual balance of the roofscape and rear elevation, causing harm to the established character and appearance of the pair. Furthermore, the difference in site levels, most notably in relation to [address], would serve to increase the perceived scale and prominence of the development.

    Consequently, the proposal would harm the character and appearance of the host dwelling and surrounding area. Therefore, it would conflict with Policy SP7 of the Tendring District Local Plan 2013 – 2033 and Beyond Section 1: [name] Section 1 Plan (2021) and Policy SPL3 of the Tendring District Local Plan 2013 – 2033 and Beyond Section 2 (2022) which seek development to make a positive contribution to the quality of the local environment and protect or enhance local character.

  5. Section 06

    Other Matters

    The appellants contend that the majority of the proposed two-storey extension and rear dormer can be constructed under the Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended) establishing a fallback position which makes the appeal proposal acceptable by comparison.

    In considering the weight to be afforded to a fallback, I must be satisfied that there is a real prospect, a greater than theoretical possibility, that the development would be carried out if the appeal were to be dismissed.

    The appellants have provided floor plans indicating the extent of two storey extension that could be achieved under permitted development, however it is unclear whether there is a greater than theoretical possibility of the fallback position being implemented, as it would not provide the amount of floorspace desired. Even if that had been demonstrated, the limitations of the legislation mean that a two-storey extension built as permitted development could not be as deep, wide or high as the proposal before me. Furthermore, it could not join up with a dormer constructed under permitted development, as is proposed here. Therefore, any such scheme would be less bulky and achieve greater separation than the appeal scheme, and would consequently be less harmful. Consequently, the fallback position does not outweigh the harm I have identified from the appeal proposal and does not justify granting planning permission.

  6. Section 07

    Conclusion and Recommendation

    The development conflicts with the development plan taken as a whole. For the reasons given above and having regard to all other matters raised I conclude that there are no material considerations that justify granting permission contrary to the development plan. Therefore, the appeal should be dismissed.

  7. Section 08

    Inspector’s Decision

    I have considered all the submitted evidence and my representative’s report and on that basis the appeal is dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 133No official casework-database value to compare
    Extracted decision date · page 1
    22 May 2026Matches the official casework database
    Extracted site visit dates
    14 April 2026 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
6005577
Application reference
26/00050/FULHH
Lead case reference
Not recorded
Planning authority
Tendring District Council
Planning authority code
E07000076

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
Not recorded
Appeal reason
refused
Type detail
Householder
Jurisdiction
No Jurisdiction Associated
Link status
Not recorded

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
0 hectares
Floor space
525 m²
Number of residences
Not recorded
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
Yes
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
26 February 2026
Valid date
26 February 2026
Start date
5 March 2026
Planning authority decision date
11 February 2026
Appeal decision date
22 May 2026

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
Not recorded
Bespoke
Not recorded
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
No
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Back Office
Dataset status
Current release
Catalogue record ID
89261
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:29
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21