Skip to main content
Official casework recordDismissedCurrent release

Appeal 6006848

Public case and site metadata stored from the official casework database, including fields that were empty in the source release.

A clearer next step

See how Inspectors approached issues like yours

Bring your planning decision into a private workspace. We separate the disputed points, then match them with source-located Inspector reasoning from similar appeals.

  • See which issues the decision appears to turn on
  • Compare the facts and open the full appeal records

One private comparison

How the refusal review works

One-off service · No subscription

Similar appeals are evidence to inspect, not a prediction of your outcome.

Official decision document

The decision, section by section

7 sections

Read the development description and the Inspector’s text from the official decision PDF in source order. Source headings are retained where available. Personal and contact details are removed by an automated privacy filter; this is source material, not Rules for You analysis.

Section 01

Development description

a single-storey rear extension.

  1. Section 02

    Decision

    The appeal is dismissed.

  2. Section 03

    Preliminary Matters

    The appellant has also submitted an appeal on the adjacent property 181 [address] (reference 6007110). Although there are similarities between the cases they must be dealt with on their own merits. [name] has been appointed to deal with that appeal.

    Under Article 3(1) and Schedule 2, Part 1, Class A of the Town and Country Planning (General Permitted Development) (England) Order 2015 as amended (the GPDO)1, planning permission is granted for the enlargement of a dwellinghouse subject to limitations and conditions.

    Where an application is made for prior approval for development which exceeds the limits in paragraph A.1(f) but is allowed by paragraph A.1(g) Part 1, paragraph A.4(3) provides that the local planning authority (LPA) may refuse the application where it considers that the proposed development does not comply – or that the developer has provided insufficient information to enable the authority to establish whether the proposed development complies with the conditions, limitations or restrictions that are applicable to such permitted development.

    [name].4(7) to Part 1 requires the LPA to assess the impact of the proposed development on the amenity of any adjoining premises where any representations have been received from the owner or occupier those premises.

  3. Section 04

    [name]

    The main issues are whether the proposed development would constitute permitted development in respect to Class A, paragraph A.1; and if the proposal is found to constitute permitted development, the effect of the proposal on the amenity of any adjoining premise. 1 All cited paragraph numbers, unless otherwise stated, are from this Part of the GPDO.

  4. Section 05

    Reasons

    The main parties agree the proposal would comply with all the criteria of paragraph A.1 except criterion (j)(iii). This requires that should the enlarged part of the dwellinghouse extend beyond a wall forming a side elevation of the original dwellinghouse, it should not have a width greater than half of the width of the original dwellinghouse.

    The appeal dwellinghouse is a 2 storey, end of terrace property with a single storey rear projection. The appellant confirms the rear projection is original2 but described it as having the side wall demolished3. On visiting the appeal site this was not the case, and the rear projection was complete and in use as part of the dwellinghouse.

    The proposal is for a full width single storey extension which would be 6.0m deep and subsume the existing rear projection. In effect the proposal would remove 2 walls of the existing rear extension and extend its depth and width.

    It is recognised that the appellant’s case revolves around the tense used in criterion (j) and were the rear projection demolished as suggested this would need to be considered. However, on submission of the appeal, and as evident during the site visit both side elevations of the original rear projection exist. Accordingly, the proposal would extend beyond a side elevation of the original dwelling and would be wider than half the width of the original dwelling. Therefore, it would not comply with criterion (j) part (iii).

    The appellant has referred to 5 appeals, 44 of which are from 2010 and dealt with enforcement and lawful development schemes under a previous version of the GPDO. Although they grapple with what should be considered a side elevation of an original dwelling, they are not limited by the prior approval process. Specifically, that prior approval must be sought before beginning the development5. Therefore, for applications submitted through the prior approval process it would stand that all parts of paragraph A.1 must be applied at the time of the decision being made.

    This is born out in the 5th appeal6 which does relate to a prior approval application, but prior to the decision being made the side elevation in question had been demolished to create a flat rear elevation.

    Therefore, although instructive these 5 appeals do not alter the above findings as the side elevation in question is still in existence. The proposal would not therefore constitute permitted development in respect of Class A, paragraph A.1.

    As considerations in relation to the amenity of any adjoining premises is a follow-on condition stage under paragraph A.4(7), it can therefore only apply if the development is otherwise permitted development. As the proposal would fail to constitute permitted development, there is no need to consider this.

  5. Section 06

    Other Matters

    The appellant has also drawn my attention to several prior approval applications from other LPAs. It is unclear whether the side elevations in question were original 2 Section 2 of the appellant’s appeal statement 3 Sections 2, 4.3 and 5 of the appellant’s appeal statement 4 APP/H5960/X/09/2115991, APP/W4705/C/09/2118544, APP/H5960/X/09/2115904 and APP/M3645/X/10/2131184 5 [name].4 (2) and (10) of Schedule 2, Part 1, Class A of the GPDO 6 APP/E0345/D/16/3160831 to the associated dwellinghouse and in existence at the time of decision, so are comparable to the scheme before me. As such they do not alter my findings.

  6. Section 07

    Conclusion

    For the reasons given above the appeal should be dismissed.

Planning inspector and document dates

The official casework attribution is grouped under a one-way keyed hash and shown only by its local identifier. Decision-letter dates and page references are extracted by fixed first-page rules and checked against that authoritative record.

  • Appeal Decision

    Extracted inspector · page 1
    Inspector attribution ID 2199No official casework-database value to compare
    Extracted decision date · page 1
    2 June 2026Matches the official casework database
    Extracted site visit dates
    13 May 2026 (page 1)

Reference and authority

Official identifiers and the planning authority recorded against this case.

Case reference
6006848
Application reference
P25/02867/PNH
Lead case reference
Not recorded
Planning authority
South Gloucestershire Council
Planning authority code
E06000025

Casework details

The casework, procedure, development and linking details supplied by the official record.

Casework type
Householder (HAS)
Procedure
Written Representations
Development type
Householder developments
Appeal type reason
Not recorded
Appeal reason
refused
Type detail
Prior Approval
Jurisdiction
No Jurisdiction Associated
Link status
Not recorded

Site and development

Published appeal-site measurements and planning designations, without the withheld precise location fields.

Site area
0 hectares
Floor space
490 m²
Number of residences
Not recorded
Site in Green Belt
No
Agricultural holding
Not recorded
Affects setting of a listed building
Yes
Historic building grant made
Not recorded
Relates to a conservation area
Not recorded
Flooding is an issue
Not recorded
Site within an AONB
Not recorded
Site within an SSSI
Not recorded

Decision and dates

The published outcome and every imported case date.

Official decision
Dismissed
Decision category
Dismissed
Received date
23 March 2026
Valid date
23 March 2026
Start date
30 March 2026
Planning authority decision date
23 January 2026
Appeal decision date
2 June 2026

Case administration

Published recovery, call-in, costs and enforcement information for this case.

Redetermined
Not recorded
Bespoke
Not recorded
Date recovered
Not recorded
Date not recovered or derecovered
Not recorded
Call-in date
Not recorded
Costs applied for
No
Enforcement grounds count
Not recorded
Enforcement grounds
Not recorded

Source and catalogue history

When this record appeared in the rolling official release and when the catalogue stored it.

Source
Planning Inspectorate casework database
Source data system
Back Office
Dataset status
Current release
Catalogue record ID
89721
First seen
20 August 2026 at 14:25
Last seen
20 August 2026 at 16:29
Removed from release
Not recorded
Record created
20 August 2026 at 14:25
Record updated
24 August 2026 at 16:21